Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Honeywell MC-TAIH22 High-Level Analog Input Field Termination Assembly

Honeywell MC-TAIH22 High-Level Analog Input Field Termination Assembly

Formulir produk

Honeywell MC-TAIH22 High-Level Analog Input Field Termination Assembly The Honeywell MC-TAIH22 51204170-150, also cataloged as the MC-TAIH22 High-Level Analog Input... Baca selengkapnya

SKU: MC-TSIA12 51303932-478
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell MC-TAIH22 High-Level Analog Input Field Termination Assembly

    The Honeywell MC-TAIH22 51204170-150, also cataloged as the MC-TAIH22 High-Level Analog Input Field Termination Assembly, operates as a dedicated hardware component for analog signal conditioning and acquisition within Honeywell Process Manager and Experion PKS I/O systems.

    Hardware Specifications

    Parameter Specification
    Model MC-TAIH22 51204170-150
    Brand Honeywell
    Origin USA
    Product Type High-Level Analog Input Field Termination Assembly
    Input Channels 16 analog input channels
    Supported Input Signals 4-20 mA, 0-10 VDC, 1-5 VDC high-level analog signals
    A/D Resolution 12-bit analog-to-digital conversion
    Accuracy +/- 0.25% of full scale
    Terminal Interface Compression screw terminals
    Isolation Channel-to-system electrical isolation
    Conformal Coating Available depending on hardware revision
    Mounting Type DIN rail or Honeywell cabinet mounting
    Weight Approximately 0.8 kg
    Dimensions Approximately 20 cm x 12.7 cm x 5 cm
    Operating Temp 0 deg C to +60 deg C
    Power Consumption Field termination assembly power consumption based on system I/O configuration

    Process Control Signal Conditioning and Isolation

    The MC-TAIH22 processes high-level analog field signals before transmission to Honeywell Process Manager and Experion PKS control platforms. The assembly accepts standard transmitter outputs, including 4-20 mA current loops and voltage inputs, then performs signal termination, filtering, and electrical isolation.

    For Honeywell process control applications, the module supports channel-to-channel isolation principles to reduce interference between independent field loops. Additionally, the hardware configuration allows integration with analog measurement devices using HART-based 4-20 mA loop communication when the connected I/O architecture supports transmitter communication functions.

    The module design supports stable analog acquisition for variables such as pressure, temperature, flow, and level measurement. Therefore, proper shielding, grounding, and signal routing practices directly affect measurement quality in industrial installations.

    Frequently Asked Questions

    Q: Does the MC-TAIH22 support direct connection of 4-20 mA transmitters?
    A: Yes. The assembly supports high-level analog inputs from 4-20 mA transmitters and other compatible voltage signal sources through its field termination channels.

    Q: Does the MC-TAIH22 provide electrical isolation between field channels and the control system?
    A: Yes. The module provides channel-to-system electrical isolation for connected analog signal paths.

    Q: Can the MC-TAIH22 be installed as a standalone analog input controller?
    A: No. The MC-TAIH22 functions as a field termination assembly and requires connection to the corresponding Honeywell Process Manager or Experion PKS I/O hardware.

    Field Installation Guidelines

    • Install the MC-TAIH22 inside the specified Honeywell cabinet or approved DIN rail mounting location.
    • Connect analog field wiring using shielded instrumentation cables where required by the installation design.
    • Terminate cable shields according to the site grounding standard to reduce electrical noise coupling.
    • Separate analog signal wiring from high-voltage power cables and switching circuits.
    • Verify field loop polarity before applying system power.
    • Confirm the configured input type matches the connected transmitter output range before commissioning.
    • Inspect terminal connections periodically to maintain proper mechanical contact.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun