    Keterangan

    Honeywell FS-TSAI-1620M Safe Analog Input Field Termination Assembly

    The Honeywell FS-TSAI-1620M, also cataloged as the FC-TSAI-1620M Safe Analog Input Field Termination Assembly, operates as a dedicated hardware component for converting field transmitter current signals into analog input voltage signals within Honeywell Safety Manager systems.

    Hardware Specifications

    Parameter Specification
    Model FS-TSAI-1620M / FC-TSAI-1620M
    Brand Honeywell
    Product Type Safe Analog Input Field Termination Assembly
    System Compatibility Honeywell Safety Manager SIS
    Origin USA
    Weight 0.3kg
    Dimensions 210 x 70 x 60 mm (L x W x H)
    Mounting Rail DIN EN TS32 / TS35 x 7.5
    Used Rail Length 211 mm
    Operating Temp Not specified
    Power Consumption 30 V DC external, 3 mA (without input loop loads)
    Approvals CE, TUV, UL, CSA, FM
    Input Channels 16 channels, arranged as 2 groups of 8 channels with common 0 V reference
    Input Signal Range 0-20 mA and 4-20 mA current loop signals
    Maximum Input Current 0-25 mA
    Input Resistance 250 ohm +/- 1%
    Output Signal to SAI-1620M 0-4 V DC
    Output Accuracy 0.10%
    Passive Transmitter Supply Output Resistance 270 ohm +/- 5%
    Igniting Current Per Channel Less than 120 mA at 30 V DC
    Fuse Rating 315 mA
    Fuse Size 5 x 20 mm
    Fuse Voltage Rating 125 V AC
    Maximum Fuse Output Current 220 mA
    Terminal Type Screw terminals
    Maximum Wire Diameter 2.5 mm2 (AWG 14)
    Wire Strip Length 7 mm
    Terminal Tightening Torque 0.5 Nm
    Field Circuit Classification Nonincendive field circuits, Class 1 Division 2
    Hydrogen Group A and B Loop Inductance Maximum 6 mH
    Hydrogen Group A and B Loop Capacitance Maximum 0.25 uF
    Non-Hydrogen Group C and D Loop Inductance Maximum 20 mH
    Non-Hydrogen Group C and D Loop Capacitance Maximum 5 uF

    4-20 mA Process Signal Interface and Isolation Characteristics

    The Honeywell FS-TSAI-1620M interfaces field-mounted analog transmitters with the SAI-1620M Safe High-Density Analog Input Module. Moreover, the assembly accepts 0-20 mA and 4-20 mA current signals and converts them into a proportional 0-4 V DC signal for module processing.

    The unit provides sixteen analog input channels divided into two eight-channel groups with a common 0 V reference. Therefore, the signal conversion path maintains consistent analog scaling between field devices and the safety input module.

    In addition, the module supports transmitter loop applications through a passive transmitter supply output with a 270 ohm output resistance. The design includes channel protection through individual 315 mA fuses and supports nonincendive field circuits for Class 1 Division 2 installation environments.

    For Honeywell process control interfaces, the analog loop architecture follows standard 4-20 mA instrumentation practices. Furthermore, engineers must verify transmitter wiring, loop resistance, and grounding arrangements before commissioning the SIS input circuit.

    Frequently Asked Questions

    Q: How many analog input channels does the FS-TSAI-1620M provide?
    A: The FS-TSAI-1620M provides sixteen analog input channels arranged as two groups of eight channels with a common 0 V reference.

    Q: What signal conversion does the field termination assembly perform?
    A: The assembly converts incoming 0-20 mA or 4-20 mA current loop signals into 0-4 V DC output signals for the SAI-1620M Safe High-Density Analog Input Module.

    Q: What type of field wiring terminals does the module use?
    A: The module uses screw terminals supporting wires up to 2.5 mm2 (AWG 14) with a 7 mm strip length and 0.5 Nm tightening torque.

    Field Installation Guidelines

    Install the FS-TSAI-1620M on compatible TS32 or TS35 x 7.5 DIN EN rails and verify mechanical fixation before wiring field circuits.

    Use separate routing paths for analog signal cables and high-current power conductors to reduce electrical interference. Moreover, connect cable shields according to the plant grounding standard and avoid creating unintended ground loops.

    Verify transmitter polarity, current loop continuity, and external 30 V DC supply wiring before applying power. Ensure field circuits remain within the specified nonincendive Class 1 Division 2 electrical limits.

    Confirm terminal tightening conditions and inspect all field connections before integrating the module with the Honeywell Safety Manager input system.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun