Honeywell FC-TRO-0824 Digital Output Module

Honeywell FC-TRO-0824 Digital Output Module

Formulir produk

Honeywell FC-TRO-0824 Digital Output Module Configured for non-safe relay output execution in Honeywell Safety Manager and Fail Safe Controller platforms,... Baca selengkapnya

SKU: FC-TRO-0824
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell FC-TRO-0824 Digital Output Module

    Configured for non-safe relay output execution in Honeywell Safety Manager and Fail Safe Controller platforms, the Honeywell FC-TRO-0824 (TRO-0824 Digital Output Module) provides direct physical switching control through eight potential-free relay changeover contacts.

    Hardware Specifications

    Parameter Specification
    Model FC-TRO-0824
    Brand Honeywell
    Product Type Non-safe Dry Digital Output Module
    Origin USA
    Weight 0.3 kg
    Dimensions 5.5 x 6.5 x 11.8 cm
    Operating Temp Not specified
    Power Consumption Typically 27 mA at 24 V DC
    Module Function Digital output interface with relay contacts
    Number of Output Channels 8
    Output Contact Type NO/NC relay changeover contacts
    Nominal Input Voltage 24 V DC
    Maximum Input Voltage 31 V DC
    Relay Cut-in Voltage 19 V DC
    Maximum Output Current 5 A
    Maximum Output Voltage 250 V AC / 300 V DC
    Maximum Switched Load 1250 VA / 150 W at 30 V DC
    AC Voltage Rating 250 V AC
    Approvals CE, UL, TUV, CSA
    Tariff Code 8537101190
    Shipment Location Xiamen, China
    Interconnection Eight-channel relay output FTA cable interface

    Channel Isolation and Process Control Interface

    The FC-TRO-0824 provides eight independent relay output channels for switching external field devices through dry potential-free contacts. The module uses relay changeover contacts with NO and NC configurations, allowing direct control of external circuits without applying field voltage to the output contacts.

    Honeywell process control modules commonly integrate channel-to-channel isolation concepts to separate field circuits and reduce electrical interference between I/O points. The FC-TRO-0824 applies relay-based signal separation for non-safe digital output applications where discrete electrical switching is required.

    The module accepts a 24 V DC supply input and operates with a typical input current of 27 mA. It supports AC and DC switching loads within the specified voltage and current limits.

    Frequently Asked Questions

    Q: What type of signals does the FC-TRO-0824 output?
    A: The FC-TRO-0824 provides eight non-safe dry digital outputs using potential-free relay changeover contacts with NO and NC terminals.

    Q: What is the maximum switching capability of the FC-TRO-0824 relay outputs?
    A: Each output supports up to 5 A switching current, with maximum ratings of 250 V AC or 300 V DC and a maximum switched load of 1250 VA or 150 W at 30 V DC.

    Q: Can the FC-TRO-0824 be used for safety shutdown functions?
    A: The FC-TRO-0824 is specified as a non-safe digital output module and should not be configured as a safety-rated output device.

    Field Installation Guidelines

    • Install the FC-TRO-0824 within the designated Honeywell controller or I/O assembly according to the system hardware manual.
    • Verify the 24 V DC supply polarity before energizing the module.
    • Use appropriate field wiring practices for relay contacts, including separation between low-level signal cables and high-voltage switching circuits.
    • Connect the interconnection cable correctly to maintain channel assignment and relay contact mapping.
    • Ground cable shields according to the control cabinet grounding standard to reduce electrical noise.
    • Confirm external load ratings remain within the specified relay voltage, current, and power limits before commissioning.
    • Inspect relay contact wiring periodically when switching inductive loads or high-frequency operating cycles.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun