Honeywell CC-TUIO31 Universal Input Output IOTA

Honeywell CC-TUIO31 Universal Input Output IOTA

Formulir produk

Honeywell CC-TUIO31 Universal Input Output IOTA Configured for universal field signal termination and analog I/O execution in Honeywell Experion PKS... Baca selengkapnya

SKU: CC-TUIO31 51306875-176
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell CC-TUIO31 Universal Input Output IOTA

    Configured for universal field signal termination and analog I/O execution in Honeywell Experion PKS control platforms, the Honeywell CC-TUIO31 (CC-TUIO31 Universal Input Output IOTA) provides direct physical and electrical interface functions for current input devices and configurable analog/digital output channels.

    Hardware Specifications

    Parameter Specification
    Model CC-TUIO31
    Brand Honeywell
    Product Type Universal Input Output IOTA
    Origin USA
    Weight 0.36 kg
    Dimensions 5.5 x 16 x 14.5 cm
    Operating Temp -40 to +70 deg C module ambient
    Power Consumption Not specified
    Input Type Current input for 2, 3, or 4 wire devices
    Input Range 0-20 mA or 4-20 mA
    A/D Converter Resolution 16 bit
    Input Scan Rate 10 ms
    Channel Configuration Any 4 channels
    Frequency Input Range 0-15 kHz
    Normal Mode Rejection Ratio 18 dB at 50 Hz, 20 dB at 60 Hz
    Crosstalk (DC to 60 Hz, channel-to-channel) 60 dB
    Output Protection Electronic short circuit protection
    Analog Communication Support HART 7
    HART Interface HART modem per channel for fast performance
    Scan Function Fast Scan (Priority I/O Module Scan)
    Safe State Function Configurable FAILOPT behavior for Digital / Analog Output channels
    Tariff Code 8537101190

    4-20 mA HART Loop Protocol and Channel Isolation Features

    The CC-TUIO31 is designed for process instrumentation signal handling within Honeywell control architectures. The module supports 4-20 mA current loops with HART 7 communication capability, allowing analog measurement signals and device diagnostic communication to be processed through the same field wiring interface.

    Channel-to-channel crosstalk performance is specified at 60 dB from DC to 60 Hz. The module provides configurable channel behavior for analog and digital output safe-state handling, with electronic short circuit protection applied to output circuits.

    The input subsystem uses a 16 bit A/D converter with a 10 ms input scan rate, supporting configurable field device connections including 2 wire, 3 wire, and 4 wire current devices.

    Frequently Asked Questions

    Q: What type of field signals can the CC-TUIO31 process?
    A: The CC-TUIO31 processes current-based field signals using 0-20 mA or 4-20 mA input ranges and supports 2 wire, 3 wire, and 4 wire device configurations.

    Q: Does the CC-TUIO31 support HART communication?
    A: Yes. The module supports HART 7 communication through a dedicated HART modem per channel for analog I/O device communication.

    Q: How are output fault conditions handled by the module?
    A: Digital and analog output channels support configurable FAILOPT safe-state behavior, and output circuits include electronic short circuit protection.

    Field Installation Guidelines

    • Install the CC-TUIO31 according to Honeywell Experion PKS I/O assembly installation procedures and approved cabinet layouts.
    • Verify field wiring polarity and terminal assignments before applying power to the I/O assembly.
    • Use shielded instrumentation cable for analog current loops where required by site electrical standards.
    • Connect cable shields according to the plant grounding specification to minimize electromagnetic interference.
    • Separate analog signal wiring from high-current power conductors and switching circuits.
    • Confirm that connected field devices match the configured 2 wire, 3 wire, or 4 wire current input arrangement.
    • Validate HART communication wiring integrity when using smart field transmitters.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun