Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Honeywell CC-TAON11 Series C Analog Output IOTA

Honeywell CC-TAON11 Series C Analog Output IOTA

Formulir produk

Honeywell CC-TAON11 Series C Analog Output IOTA Configured for analog output signal termination in the Honeywell Experion PKS Series C... Baca selengkapnya

SKU: CC-TAON11 51306521-175
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell CC-TAON11 Series C Analog Output IOTA

    Configured for analog output signal termination in the Honeywell Experion PKS Series C system, the Honeywell CC-TAON11 (51306521-175) (CC-TAON11 Analog Output IOTA) provides direct electrical execution. It functions as the termination interface between Series C analog output modules and field devices, routing controller-generated 4-20 mA output signals to external loads while supporting redundant I/O configurations.

    Suffix Breakdown & Model Matrix

    The supplied documentation identifies a single catalog number only. No official suffix or option matrix is specified.

    Parameter Specification
    Model CC-TAON11 (51306521-175)
    Brand Honeywell
    Origin USA
    Weight Approx. 0.4 kg to 0.56 kg
    Dimensions Not specified
    Operating Temp -40 deg C to +70 deg C
    Power Consumption Not specified
    Product Type Analog Output Input Output Termination Assembly (IOTA)
    System Compatibility Experion PKS Series C
    Module Type Analog Output Termination Assembly
    HART Support Non-HART
    Redundancy Supports redundant configuration (12-inch version)
    Number of Channels 16
    Output Signal 4-20 mA current loop
    Signal Resolution 12-bit or 16-bit processing (depends on paired I/O module)
    Output Ripple Less than 100 mV peak-to-peak across a 250 Ohm load at power line frequency
    Output Readback Accuracy +/- 4 % of full scale
    Output Current Linearity +/- 0.05 % of full scale nominal
    Temperature Drift 0.005 % of full scale per deg C
    Isolation Galvanic isolation between channels and power supply
    Storage Temperature -40 deg C to +85 deg C
    Relative Humidity 5 % to 95 % RH, non-condensing
    Mounting DIN rail

    Channel-to-Channel Isolation

    The CC-TAON11 provides galvanic isolation between field channels and the power supply to reduce the transfer of electrical disturbances into analog output circuits. The assembly is intended for standard 4-20 mA control loops and does not implement HART communication. Internal diagnostics support output signal verification, while open-wire detection identifies interrupted field wiring connected to actuators or other analog loads.

    Frequently Asked Questions

    Q: Does the CC-TAON11 support HART communication?
    A: No. The documented version is a non-HART Analog Output IOTA intended for standard 4-20 mA analog output applications.

    Q: Can the module be installed in a redundant I/O configuration?
    A: Yes. The documentation specifies support for redundant configuration when used with the applicable 12-inch redundant arrangement.

    Q: Does the termination assembly require firmware updates?
    A: No firmware information is specified for the IOTA itself. Functional compatibility depends on the associated Series C analog output module and the Experion PKS hardware configuration.

    Field Installation Guidelines

    • Mount the IOTA securely on the designated DIN rail inside the Series C cabinet.
    • Verify that the installed analog output module matches the specified CC-TAON11 termination assembly before field wiring.
    • Route analog output wiring separately from high-voltage or high-current conductors to reduce electrical interference.
    • Terminate cable shields according to the cabinet grounding practice defined for the control system, avoiding multiple shield ground points unless required by the installation standard.
    • Confirm terminal identification before energizing field circuits and verify continuity if open-wire diagnostics indicate a disconnected load.
    • Observe the specified environmental limits for operating temperature and humidity during installation and operation.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun