Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Honeywell CC-PFB802 Series C Fieldbus Interface Module

Honeywell CC-PFB802 Series C Fieldbus Interface Module

Formulir produk

Honeywell CC-PFB802 Series C Fieldbus Interface Module Configured for FOUNDATION Fieldbus H1 communication within the Experion PKS platform, the Honeywell... Baca selengkapnya

SKU: CC-PFB802
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell CC-PFB802 Series C Fieldbus Interface Module

    Configured for FOUNDATION Fieldbus H1 communication within the Experion PKS platform, the Honeywell CC-PFB802 (51454953-176) (CC-PFB802 Fieldbus Interface Module) provides direct electrical interface functions between the controller infrastructure and H1 field segments. The module supports up to eight FOUNDATION Fieldbus H1 networks, device communication scheduling, and redundant deployment for compatible Experion PKS Revision R400 or later systems.

    Suffix Breakdown & Model Matrix

    The available documentation identifies CC-PFB802 (Part Number: 51454953-176) as a fixed catalog configuration. No official suffix matrix or configurable ordering code breakdown is specified.

    Hardware Specifications

    Parameter Specification
    Model CC-PFB802 (51454953-176)
    Brand Honeywell
    Origin USA
    Product Type Series C Fieldbus Interface Module (FIM8)
    Communication Protocol FOUNDATION Fieldbus H1
    System Compatibility Honeywell Experion PKS Revision R400 or later
    H1 Networks Up to 8
    Maximum Devices per H1 Network Up to 16 field devices
    Communication Speed 31.25 kbps
    Configurable Macrocycle Periods 250 ms, 500 ms, 1 s, 2 s, 4 s, 8 s, 16 s, 32 s
    Redundancy Supported (single or redundant pair configuration)
    Input Supply 24 VDC
    Coating Conformal coating
    Dimensions Approximately 120 mm x 80 mm x 40 mm (mounting assembly dependent)
    Weight Approximately 0.3 kg to 0.64 kg (housing dependent); another published configuration lists approximately 0.8 kg
    Operating Temp -40 deg C to 70 deg C
    Storage Temp -40 deg C to 85 deg C
    Mounting DIN rail or panel mounting with compatible IOTA
    Compliance CE, RoHS
    Power Consumption Not specified by manufacturer

    FOUNDATION Fieldbus H1 Connectivity

    The CC-PFB802 implements FOUNDATION Fieldbus H1 communication for Series C architectures. Each module supports up to eight independent H1 segments with scheduled communication based on configurable macrocycle periods. Redundant module installation is supported where the associated Experion PKS architecture is configured for redundant operation. LED indicators provide local status for module operation, power, Fault Tolerant Ethernet (FTE), and individual fieldbus link status.

    Frequently Asked Questions

    Q: Does the CC-PFB802 support redundant operation?
    A: Yes. The module supports installation as either a standalone interface or as a redundant pair when the corresponding Experion PKS hardware and system configuration support redundancy.

    Q: Can the module be hot-swapped during operation?
    A: The supplied documentation does not specify hot-swap capability. Replacement procedures should follow the maintenance instructions applicable to the installed Experion PKS Series C cabinet and IOTA assembly.

    Q: Is firmware compatibility dependent on the Experion PKS revision?
    A: Yes. The available documentation identifies compatibility with Experion PKS Revision R400 or later. Firmware and system software revisions should be verified before installation.

    Field Installation Guidelines

    • Verify that the installed IOTA is compatible with the CC-PFB802 module before insertion.
    • Confirm a stable 24 VDC power source before energizing the fieldbus interface.
    • Route FOUNDATION Fieldbus trunk and spur wiring in accordance with the applicable fieldbus installation standard and maintain cable shielding continuity.
    • Bond cable shields according to the site grounding philosophy to minimize communication noise.
    • Observe the minimum bending radius specified for the selected fieldbus cable.
    • Confirm segment addressing, termination, and device loading before commissioning each H1 network.
    • Verify module and network status using the front-panel LED indicators after power-up.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun