Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Honeywell CC-PAIH02 51405038-375 Analog Input Module

Honeywell CC-PAIH02 51405038-375 Analog Input Module

Formulir produk

Honeywell CC-PAIH02 51405038-375 Analog Input Module Configured for multi-channel field signal acquisition in Honeywell Experion PKS C300 controller architectures, the... Baca selengkapnya

SKU: CC-PAIH02 51405038-375
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell CC-PAIH02 51405038-375 Analog Input Module

    Configured for multi-channel field signal acquisition in Honeywell Experion PKS C300 controller architectures, the Honeywell CC-PAIH02 51405038-375 (CC-PAIH02 Analog Input Module) provides direct electrical conditioning and A/D conversion of process-level analog signals into controller-readable digital data within distributed I/O backplane environments.

    The module supports 16 channel differential/single-ended input acquisition for 2-wire or self-powered transmitters. It processes 4-20 mA and voltage signals through configurable input ranges with 16-bit resolution conversion. Channel acquisition is executed via a 50 ms scan cycle, with integrated filtering and rejection mechanisms for industrial noise environments.

    Suffix Breakdown & Model Matrix

    • Base Model: CC-PAIH02
    • Order Number: 51405038-375
    • Module Class: Analog Input Module
    • Functional Variant: High level analog input with multi-range conditioning
      No additional decoded hierarchy is defined in manufacturer documentation for suffix segmentation beyond ordering and base functional class.

    Hardware Specifications

    Parameter Specification
    Model CC-PAIH02 51405038-375
    Brand Honeywell
    Origin USA
    Weight 0.4 kg
    Dimensions 6 x 15.5 x 14.5 cm
    Operating Temp Not specified
    Power Consumption Not specified
    Input Type 2-wire or self-powered transmitters
    Input Channels 16 channels
    A/D Resolution 16 bits
    Input Range 0-5 V, 1-5 V, 0.4-2 V, 4-20 mA (250 ohm)
    Scan Rate 50 ms
    Common Mode Rejection 70 dB (dc to 60 Hz)
    Normal Mode Rejection 19 dB at 60 Hz
    Input Impedance > 10 M ohm (powered)
    Maximum Input +/- 30 V
    Crosstalk -60 dB (dc to 60 Hz)

    Honeywell Process Signal Conditioning Characteristics

    The module implements channel-level analog signal conditioning consistent with Honeywell Experion PKS I/O architecture. Each input channel supports loop-powered 4-20 mA acquisition through precision shunt conversion (250 ohm equivalent scaling path), enabling direct interfacing with field transmitters under HART-capable process loops. Differential measurement paths are designed to maintain channel integrity under common-mode voltage excursions within defined industrial limits, with multi-stage filtering providing attenuation of normal-mode interference prior to A/D conversion. Backplane communication ensures synchronized scan scheduling with controller execution cycles, maintaining deterministic update behavior across distributed I/O nodes.

    Frequently Asked Questions (FAQ)

    Q: Does the CC-PAIH02 support hot-swap replacement during controller operation?
    A: Hot-swap capability depends on system rack configuration. Electrically, the module is designed for backplane isolation; however, insertion/removal should follow system-level maintenance procedures to avoid bus disruption.

    Q: What is the impact of channel-to-channel interaction under high-density loading?
    A: Crosstalk is specified at -60 dB (dc to 60 Hz), indicating low inter-channel coupling under normal operating bandwidth, assuming correct grounding and shield termination practices.

    Q: Can the module directly interface with both voltage and current inputs simultaneously?
    A: Yes. Input channels are configurable for 0-5 V, 1-5 V, 0.4-2 V, and 4-20 mA signal types, but configuration must be consistent per channel grouping rules defined at system integration level.

    Field Installation Guidelines

    • Install module in designated Experion PKS I/O chassis slot with verified backplane alignment.
    • Maintain shield continuity and terminate cable shields at designated grounding points only.
    • Separate analog input wiring from high-voltage switching conductors to reduce electromagnetic coupling.
    • Ensure correct configuration of channel input type before energizing field loops.
    • Verify loop power compatibility for 2-wire transmitters prior to connection.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun