Honeywell 900C50S-0460 HC900 CPU Module

Honeywell 900C50S-0460 HC900 CPU Module

Formulir produk

Honeywell 900C50S-0460 HC900 CPU Module Configured for safety HVAC control execution in Honeywell HC900 Hybrid Controller systems, the Honeywell 900C50S-0460... Baca selengkapnya

SKU: 900C50S-0460
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell 900C50S-0460 HC900 CPU Module

    Configured for safety HVAC control execution in Honeywell HC900 Hybrid Controller systems, the Honeywell 900C50S-0460 (900C50S-0460 CPU Module) provides direct processing and communication functions for controller operations, I/O management, and serial network interfaces.

    Hardware Specifications

    Parameter Specification
    Model 900C50S-0460
    Brand Honeywell
    Product Type CPU Module
    System Platform HC900 Hybrid Controller
    Application Function SIL-2 Safety HVAC Control Unit
    Processor Memory 128 MB battery backed DDR2 RAM
    Ethernet Interface Dual Ethernet ports
    Serial Interface 2 isolated RS-485 ports
    I/O Capacity Up to 512 points per controller
    Analog or Digital I/O Capability Up to 4068 analog or digital I/O points
    Power Supply 24 VDC (18-36 V)
    Power Consumption 15 W typical, 25 W maximum
    Operating Temp -40 deg C to +70 deg C
    Weight 0.4 kg
    Dimensions 13.7 x 3.6 x 5.4 cm
    Origin USA
    Shipment Location Xiamen, China
    Tariff Code 8537101190

    HC900 Controller Communication and Process Interface

    The Honeywell 900C50S-0460 CPU module manages controller execution, data processing, and communication exchange within the HC900 Hybrid Controller architecture. It supports dual Ethernet communication channels and isolated RS-485 interfaces for connection with distributed control devices and field communication networks.

    Furthermore, the module provides 128 MB battery backed DDR2 RAM for retaining controller data during power interruptions. The CPU processes logic execution, I/O scanning, and control sequence operations for connected HC900 input and output modules.

    For Honeywell process control applications, the controller architecture supports industrial signal handling functions including 4-20 mA HART loop protocol integration, FOUNDATION Fieldbus and Profibus PA connectivity through compatible interface modules, and channel-to-channel isolation for field signal separation.

    Frequently Asked Questions

    Q: What communication interfaces are available on the Honeywell 900C50S-0460 CPU Module?
    A: The module provides dual Ethernet ports and 2 isolated RS-485 ports for controller communication and serial device integration.

    Q: What memory configuration does the 900C50S-0460 use?
    A: The CPU module uses 128 MB battery backed DDR2 RAM for controller program storage and operational data retention.

    Q: Can the 900C50S-0460 support large I/O configurations?
    A: The module supports up to 512 I/O points per controller and can manage analog or digital I/O configurations according to HC900 system architecture requirements.

    Field Installation Guidelines

    Install the Honeywell 900C50S-0460 CPU module in the designated HC900 controller rack position according to the system hardware configuration.

    Connect Ethernet and RS-485 communication wiring using appropriate industrial cable routing practices. Keep communication cables separated from high-voltage power conductors to reduce electrical interference.

    Terminate cable shields according to the site grounding standard. Avoid multiple grounding points on shielded communication cables unless the system design specifies a multi-point grounding method.

    Verify the 24 VDC power supply polarity and voltage range before energizing the controller. Confirm that all connected I/O modules and communication interfaces match the configured HC900 firmware and hardware revision requirements.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama