Honeywell 900A16-0101 HC900 High-Level Analog Input Module

Honeywell 900A16-0101 HC900 High-Level Analog Input Module

Formulir produk

Honeywell 900A16-0101 HC900 High-Level Analog Input Module Configured for high-level analog signal acquisition in Honeywell HC900 / ControlEdge 900 systems,... Baca selengkapnya

SKU: 900A16-0101
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell 900A16-0101 HC900 High-Level Analog Input Module

    Configured for high-level analog signal acquisition in Honeywell HC900 / ControlEdge 900 systems, the Honeywell 900A16-0101 (900A16-0101 High-Level Analog Input Module) provides direct physical signal conversion for voltage and current field inputs.

    Hardware Specifications

    Parameter Specification
    Model 900A16-0101
    Brand Honeywell
    Product Type High-Level Analog Input Module
    Series HC900 / ControlEdge 900
    Input Channels 16 isolated analog input channels
    Input Signal Types Configurable voltage and current inputs
    Input Ranges 0-10 V, +/- 10 V, 0-20 mA, 4-20 mA
    A/D Resolution 15 bit
    Accuracy Factory calibrated: +/- 0.1% of range; Field calibrated: +/- 0.05% of range
    Update Rate 100 ms parallel module update
    Input Impedance Greater than 1 Mohm for voltage input; 250 ohm for current input with shunt resistor
    Channel Isolation Up to 400 VDC channel-to-channel isolation
    Logic Isolation Up to 1000 VDC channel-to-backplane isolation
    Backplane Power Consumption 5 VDC, 75 mA max
    External Supply Consumption 24 VDC, 50 mA max
    Noise Rejection CMRR greater than 90 dB at 120 VAC; SMRR greater than 31 dB
    Operating Temp 0 deg C to 60 deg C
    Storage Temp -40 deg C to 85 deg C
    Relative Humidity 10% to 90% non-condensing
    Estimated Shipping Size 13.3 x 3 x 14.5 cm
    Weight 0.2 kg

    Honeywell Process Signal Interface Characteristics

    The 900A16-0101 module processes standard process instrumentation signals through configurable analog input channels. Each channel accepts voltage or current inputs independently, which allows mixed signal measurement within the same module.

    The module supports 4-20 mA HART loop protocol applications when used with compatible external transmitters and system configurations. Additionally, the channel-to-channel isolation structure separates field circuits and reduces signal interaction during multi-point analog measurement.

    The integrated 250 ohm current shunt resistor can be enabled through onboard DIP switch settings. Therefore, external precision resistors are not required for standard current loop measurement configurations.

    Frequently Asked Questions

    Q: Does the Honeywell 900A16-0101 support mixed analog input types on one module?
    A: Yes. Each of the 16 input channels can be configured independently for voltage or current signal measurement.

    Q: Does the module provide electrical isolation between input channels?
    A: Yes. The module provides galvanic isolation between individual channels and between field input circuits and the HC900 backplane.

    Q: What power supply interface does the 900A16-0101 use?
    A: The module receives backplane power from the HC900 system and requires 5 VDC backplane power with an additional 24 VDC supply connection.

    Field Installation Guidelines

    Install the 900A16-0101 module in the designated HC900 / ControlEdge 900 rack position according to the controller hardware configuration manual.

    Connect analog field wiring using shielded instrumentation cable where required. Ground cable shields at the recommended single grounding point to reduce electromagnetic interference.

    Separate analog signal wiring from high-voltage power cables and switching circuits. Verify polarity, signal range configuration, and channel settings before applying field power.

    Check module LED status indicators after installation. Confirm normal module operation through the controller configuration software before placing the analog channels into process service.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama