Honeywell 8C-TAIM01 Analog Input Module Configured for thermocouple and RTD signal acquisition in the Honeywell Experion PKS Series 8 I/O...
Baca selengkapnya
SKU: 51306999-175 8C-TAIM01 8U-TAIM01
Negara asal: USA
Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .
Hubungi kami: +86 135 995 07613
Tersedia pada hari kerja antara pukul 09.00 hingga 18.00
Email kami: sales2@industriaxplc.com
Tersedia 24/7 untuk pertanyaan dan dukungan
Keterangan
Honeywell 8C-TAIM01 Analog Input Module
Configured for thermocouple and RTD signal acquisition in the Honeywell Experion PKS Series 8 I/O system, the Honeywell 8C-TAIM01 51306999-175 (8C-TAIM01 Analog Input Module) provides direct physical signal conversion and isolated measurement execution.
Hardware Specifications
Parameter
Specification
Model
8C-TAIM01 51306999-175
Brand
Honeywell
Product Type
Analog Input Module
System Platform
Honeywell Experion PKS Series 8 I/O
Origin
USA
Weight
0.24 kg
Dimensions
14.5 x 12 x 5 cm
Input Type
Thermocouple and / or RTD
Input Channels
64 fully-isolated channel-to-channel inputs
Input Scan Rate
1 Second fixed by IOM
Channel Bandwidth
0 to 4.7 Hz (-3 dB)
Nominal Input Range
-20 to +100 mV
Temperature Stability
+/-20 ppm per deg C max
Long Term Drift
500 ppm
Isolation Type
Channel-to-channel electrical isolation
Channel Isolation and Process Signal Handling
The Honeywell 8C-TAIM01 51306999-175 processes thermocouple and RTD field signals through 64 fully-isolated input channels. Therefore, each measurement channel maintains electrical separation from adjacent inputs to reduce field wiring interference.
The module supports temperature measurement applications where cold junction compensation (CJC) and sensor linearization functions are managed through the Series 8 I/O processing architecture. Additionally, the input bandwidth of 0 to 4.7 Hz (-3 dB) defines the signal response range for temperature-related process variables.
Unlike current loop input modules designed for 4-20 mA HART signals, this module directly accepts millivolt-level thermocouple signals and resistance-based RTD measurements. Consequently, sensor type selection and field termination configuration determine the final measurement behavior.
Frequently Asked Questions
Q: What field signals does the 8C-TAIM01 51306999-175 accept? A: The module accepts thermocouple and RTD input signals through 64 fully-isolated channels. It supports a nominal input range of -20 to +100 mV.
Q: Does the module provide channel-to-channel isolation? A: Yes. The 8C-TAIM01 provides fully-isolated channel-to-channel inputs, which separates individual measurement circuits and reduces electrical coupling between field signals.
Q: What is the fixed input scan rate of this module? A: The input scan rate is 1 Second and is fixed by the associated Series 8 I/O Module (IOM) processing architecture.
Field Installation Guidelines
Install the 8C-TAIM01 51306999-175 module in the designated Honeywell Series 8 I/O mounting assembly according to the system hardware configuration requirements.
Use shielded field wiring for thermocouple and RTD connections where the installation environment contains electrical noise sources. Connect cable shields according to the site grounding standard and avoid parallel routing with high-current power conductors.
Verify correct sensor wiring polarity before energizing the I/O assembly. Thermocouple connections require correct lead identification because reversed polarity affects temperature measurement direction. RTD wiring should maintain consistent conductor routing to minimize resistance measurement errors.
Confirm that field terminals, I/O connectors, and module seating are mechanically secure before system commissioning. Perform channel verification through the Experion PKS engineering tools after installation.