Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin URSHB UR-SHB High-Voltage Power Supply Module

GE Multilin URSHB UR-SHB High-Voltage Power Supply Module

Formulir produk

GE Multilin URSHB UR-SHB High-Voltage Power Supply Module The GE Multilin URSHB, also designated as the URSHB High-Voltage Power Supply Module, operates as... Baca selengkapnya

SKU: URSHB
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin URSHB UR-SHB High-Voltage Power Supply Module

    The GE Multilin URSHB, also designated as the URSHB High-Voltage Power Supply Module, operates as a dedicated hardware component for regulated DC power conversion within GE Multilin Universal Relay (UR) platforms. It converts external AC/DC auxiliary sources into internal relay supply buses.

    Hardware Specifications

    Parameter Specification
    Model URSHB (UR-SHB)
    Brand General Electric (GE Grid Solutions / Multilin)
    Weight 0.8 lbs
    Dimensions 8.2 cm x 12.2 cm x 6.0 cm
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Approx. 0.75 A max current input
    Module Type High-Voltage Power Supply Module
    Compatible Platform GE Multilin Universal Relay (UR) Series
    Installation Method Plug-and-play modular slide-in unit
    DC Input Voltage 110 - 250 VDC nominal; 88 - 300 VDC operating range
    AC Input Voltage 100 - 240 VAC, 50/60 Hz nominal; 88 - 265 VAC operating range
    Ride-Through Time >= 30 ms at nominal input

    Industrial Control Power Conversion Characteristics

    The URSHB module integrates with GE Multilin Universal Relay chassis power architecture through the dedicated power supply slot (Slot A). It provides regulated internal DC buses for the relay processor, communication modules, digital I/O modules, and CT/VT measurement assemblies.

    The module incorporates electrical transient immunity features, power-fail diagnostic monitoring, and internal self-test functions for relay system supervision. The power conversion stage maintains stable DC output under substation auxiliary AC and DC supply conditions.

    The module supports GE Multilin UR platform configurations including B30, L90, T60, G60, and C60 relay families where compatible chassis hardware is installed.

    Backplane Bus Communication and Firmware Compatibility

    The URSHB power module interfaces with the Universal Relay backplane power distribution system rather than providing external field communication. Its operation depends on chassis-level power routing, module recognition, and firmware compatibility between installed relay components.

    The modular slide-in construction allows integration with UR series rack assemblies while maintaining controlled power delivery to processor and I/O expansion cards. Installation requires verification of chassis compatibility and correct power supply slot assignment.

    Frequently Asked Questions

    Q: What slot position is required for the URSHB module in a GE Multilin UR chassis?
    A: The URSHB is installed in Slot A, which is the dedicated power supply position of the Universal Relay chassis.

    Q: What input power sources can the URSHB accept?
    A: The module accepts high-voltage auxiliary AC or DC control power inputs, including 88 - 300 VDC and 88 - 265 VAC operating ranges.

    Q: Does the URSHB provide field signal processing functions?
    A: No. The URSHB is a power conversion module and does not perform relay protection algorithms, I/O processing, or communication functions.

    Field Installation Guidelines

    Install the URSHB only in the designated power supply slot of a compatible GE Multilin Universal Relay chassis. Confirm that the auxiliary power source matches the specified AC/DC input range before energizing the module.

    Maintain proper cabinet grounding and ensure protective earth bonding is completed according to substation installation practices. Separate high-voltage auxiliary power wiring from low-level communication and measurement signal wiring to reduce electrical interference.

    For replacement installation, remove input power before extracting or inserting the module. Verify connector alignment, chassis seating, and mechanical locking engagement before restoring power.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun