Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin UR9CH Universal Relay Chassis Module

GE Multilin UR9CH Universal Relay Chassis Module

Formulir produk

GE Multilin UR9CH Universal Relay Chassis Module Configured for modular protection hardware integration in GE Multilin Universal Relay platforms, the GE... Baca selengkapnya

SKU: UR9CH
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin UR9CH Universal Relay Chassis Module

    Configured for modular protection hardware integration in GE Multilin Universal Relay platforms, the GE Multilin UR9CH (UR9CH Universal Relay Chassis Module) provides the mechanical and electrical infrastructure for housing protection, control, communication, and I/O modules. The chassis supports module backplane connections, power distribution, and deterministic inter-module data exchange within UR series relay systems.

    Hardware Specifications

    Parameter Specification
    Model UR9CH
    Brand GE Multilin
    Weight 1 lb
    Dimensions 6.5 in L x 6 in W x 2.5 in H
    Operating Temp -40 deg C to +60 deg C
    Power Consumption 25 W to 45 W typical, depending on installed modules
    Series Universal Relay (UR) Series
    Form Factor 19-inch rack mount, 9U height
    Module Capacity Up to 16 vertical module slots
    Mounting Options Rack mount, panel mount, surface mount
    Power Supply Compatibility 88-300 VDC / 88-265 VAC high range; 24-48 VDC low range
    Protection Rating IP40 front panel, IP20 rear terminals
    Supported Modules CPU, CT/VT input, Digital I/O, communication cards, Ethernet interfaces

    Deterministic Backplane Communication and Firmware Compatibility

    The UR9CH chassis uses the Universal Relay internal backplane architecture to provide module-to-module communication and power distribution between installed functional cards. The backplane supports deterministic data transfer for protection logic execution, event timestamp synchronization, and coordinated operation between CPU, input, output, and communication modules.

    Industrial control compatibility depends on installed relay firmware and module combinations. Firmware flash compatibility must be verified between the chassis configuration, CPU module, communication cards, and protection application modules before system commissioning.

    Frequently Asked Questions

    Q: Does the UR9CH support hot-swappable modules?
    A: The chassis supports redundant hot-swappable power supply configurations. Module replacement procedures depend on the installed relay hardware configuration and approved maintenance procedures.

    Q: How many functional modules can be installed in the UR9CH chassis?
    A: The chassis provides up to 16 vertical module slots, with the final capacity determined by the installed backplane and relay configuration.

    Q: What power supply ranges are supported by the UR9CH platform?
    A: The chassis supports high-range power inputs of 88-300 VDC or 88-265 VAC and low-range power inputs of 24-48 VDC through compatible power supply modules.

    Field Installation Guidelines

    Install the UR9CH chassis in a compatible 19-inch protection rack or approved panel mounting structure. Verify mechanical alignment of module guides and backplane connectors before inserting functional cards.

    Maintain proper separation between power wiring, CT/VT signal wiring, communication cables, and low-level I/O conductors. Use shielded communication cables where required and terminate cable shields according to the grounding design of the protection panel.

    Confirm chassis grounding continuity before energizing the system. Inspect rear terminal connections, power supply module seating, and communication interface installation prior to relay configuration loading.

    For replacement or expansion activities, remove power according to site maintenance procedures before accessing chassis modules. Confirm firmware compatibility between CPU, communication modules, and installed protection cards before restoring operation.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun