    GE Multilin UR8GV UR-8GV CT/VT Input Module

    Configured for CT and VT signal acquisition in GE Multilin Universal Relay platforms, the GE Multilin UR-8GV (UR-8GV CT/VT Input Module) provides direct physical/electrical execution for protective measurement, metering, and disturbance recording functions.

    Hardware Specifications

    Parameter Specification
    Model UR-8GV
    Brand GE Multilin
    Origin Canada
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Not specified in provided data
    Module Type Combined CT/VT AC Input Module
    Frequency Input 50 Hz / 60 Hz auto-sensing and configurable
    CT Inputs 1 A or 5 A nominal secondary current, selectable by order option
    CT Thermal Withstand 20 A continuous, 500 A for 1 second
    CT Burden < 0.2 VA at rated current
    VT Inputs 60 V to 240 V AC phase-to-neutral
    VT Maximum Continuous Voltage 300 V AC
    VT Burden < 0.15 VA at 120 V
    Sampling Rate Up to 128 samples per cycle
    Current Accuracy +/- 0.25% of reading from 0.1 to 2.0 x IN
    Voltage Accuracy +/- 0.25% of reading from 10 V to 208 V
    Frequency Accuracy +/- 0.01 Hz
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity Up to 95% non-condensing
    Terminal Type High-current screw-clamp and draw-out shorting block terminals

    Deterministic Network and Protection Processing Characteristics

    The UR-8GV module operates as an analog acquisition interface inside GE Multilin Universal Relay platforms. It converts CT and VT secondary signals into digitized measurement data used by relay protection algorithms, phasor calculations, oscillography, and power quality analysis.

    The module provides CT shorting functionality during removal from the relay chassis to maintain a closed current transformer secondary circuit. The input design supports neutral current measurement, ground fault detection, zero-sequence protection schemes, and harmonic analysis up to the 25th harmonic.

    The CT/VT channels are processed with relay internal sampling architecture for time-aligned protection calculations. The module interfaces with UR series protective relays including C60, T60, L90, D60, and B30 platforms.

    Frequently Asked Questions

    Q: Does the UR-8GV support hot-swap removal while CT circuits are connected?
    A: The module includes an automatic CT shorting mechanism that shorts CT secondary circuits during module removal. Maintenance procedures must follow the relay manufacturer's installation instructions.

    Q: What type of signals are processed by the UR-8GV module?
    A: The module processes secondary current signals from CTs and secondary voltage signals from VTs for protection, metering, and recording functions.

    Q: What terminal design is used for CT connections?
    A: The module uses high-current screw-clamp and draw-out shorting block terminals designed for CT circuit safety during maintenance operations.

    Field Installation Guidelines

    Install the UR-8GV module only in compatible GE Multilin Universal Relay chassis slots. Verify chassis configuration, terminal assignments, and relay firmware compatibility before installation.

    Connect CT wiring using the designated shorting terminal arrangement and maintain correct polarity between instrument transformers and relay inputs. Keep CT and VT signal wiring separated from high-current power conductors to reduce induced electrical noise.

    Use shielded signal cables where required by the installation design. Connect cable shields according to site grounding practices and avoid multiple unintended grounding paths.

    Confirm that VT secondary voltage levels match the configured relay input range before energizing the module. Inspect terminal tightness, connector engagement, and module seating position after installation.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun