Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin UR7CH UR-7CH Universal Relay Chassis

GE Multilin UR7CH UR-7CH Universal Relay Chassis

Formulir produk

GE Multilin UR7CH UR-7CH Universal Relay Chassis The GE Multilin UR7CH, also cataloged as the UR7CH Universal Relay Chassis, operates as a dedicated... Baca selengkapnya

SKU: UR7CH
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin UR7CH UR-7CH Universal Relay Chassis

    The GE Multilin UR7CH, also cataloged as the UR7CH Universal Relay Chassis, operates as a dedicated hardware component for modular rack enclosure and system module integration within GE Universal Relay (UR) protection and control platforms.

    Hardware Specifications

    Parameter Specification
    Model UR7CH
    Brand GE Multilin
    Weight 0.5 kg
    Dimensions 7U height, 19.0 in / 482.6 mm width, 8.82 in / 224.0 mm depth excluding wiring terminals
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Dependent on installed UR modules and system configuration
    Chassis Design 19-inch rack mount horizontal chassis
    Module Capacity Up to 19 vertical module slots depending on backplane configuration
    Housing Material Heavy-gauge aluminum / steel enclosure with protective coating
    Protection Class IP40 front panel, IP20 rear terminals
    Compatible Platform GE Universal Relay (UR) Series

    Profinet / EtherNet-IP Deterministic Networks and I/O Density Scaling

    The GE Multilin UR7CH is designed as a modular hardware carrier for GE UR protection platforms, supporting high-density installation of CPU modules, power supply modules, CT/VT input modules, digital I/O cards, and communication interfaces. The chassis backplane provides mechanical alignment and electrical interconnection between installed UR plug-in modules.

    The modular slot arrangement enables I/O density scaling by allowing different combinations of protection, monitoring, and communication modules within the same enclosure. Firmware flash compatibility and module-level configuration management depend on the specific UR device modules installed in the chassis.

    The chassis construction supports installation in electrically noisy substation environments where module separation, grounding practices, and controlled wiring routing are required for stable signal processing.

    Frequently Asked Questions

    Q: Does the UR7CH chassis contain an independent protection processor?
    A: No. The UR7CH is a passive modular chassis structure. Protection processing functions are performed by installed GE UR CPU and application modules.

    Q: Can UR modules be replaced while the chassis is energized?
    A: Hot-swap capability depends on the installed UR module type and system configuration. Module replacement procedures must follow GE specified maintenance requirements and power isolation practices.

    Q: How is communication between installed UR modules maintained?
    A: Installed modules communicate through the chassis backplane interface. Communication functions depend on the specific CPU, I/O, and communication modules installed.

    Field Installation Guidelines

    Install the UR7CH chassis in a compatible 19-inch equipment rack with sufficient mechanical support for the chassis weight and installed modules.

    Verify that the rack grounding system provides a low-impedance protective earth connection. Shielded signal cables should be routed separately from high-voltage power conductors and connected according to the installed module wiring requirements.

    Maintain correct module insertion alignment during installation to prevent damage to backplane connectors. Ensure rear terminal wiring is secured and arranged to avoid excessive mechanical stress on terminal blocks.

    Environmental installation should maintain the specified operating temperature and humidity limits. Avoid locations with direct water exposure, excessive vibration, or uncontrolled electromagnetic interference sources.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun