    Keterangan

    GE Multilin UR4DH UR-4DH Universal Relay Hardware Module

    Configured for protective control signal processing in the GE Multilin Universal Relay (UR) Series platform, the GE Multilin UR4DH (UR4DH Hardware Module) provides direct physical/electrical execution within modular relay chassis architectures.

    Hardware Specifications

    Parameter Specification
    Model UR4DH
    Brand GE Multilin (General Electric)
    Origin United States
    Operating Temp -40 deg C to +60 deg C
    Product Line Universal Relay (UR) Series
    Module Type Hardware / Control Module
    Chassis Compatibility GE Multilin UR modular chassis platforms
    Communication Support IEC 61850, Modbus RTU/TCP, DNP 3.0
    Dielectric Test 2.0 kV AC for 1 minute (IEC 60255-5)
    Impulse Voltage Withstand 5 kV (IEC 60255-5)
    Humidity Range 5% to 95% non-condensing

    Profinet / EtherNet-IP Deterministic Network and I/O Architecture

    The GE Multilin UR4DH is integrated into the Universal Relay modular architecture for coordinated protection, control, and automation functions. The module operates through the UR chassis backplane interface, enabling internal data exchange between relay processing units, input/output assemblies, and communication components.

    The UR platform supports deterministic industrial communication structures, including IEC 61850, Modbus RTU/TCP, and DNP 3.0 protocols. The module design supports sequence-of-events (SOE) recording, event logging, and low-latency protective action execution through the relay system firmware environment.

    The UR4DH hardware construction incorporates electrical immunity design considerations for protection equipment applications, including resistance to electrical noise, surge conditions, and EMI/RFI interference according to applicable protection relay standards.

    Frequently Asked Questions (FAQ)

    Q: Is the GE Multilin UR4DH designed for hot-swap replacement?
    A: The UR4DH supports modular maintenance procedures within compatible GE Multilin UR chassis configurations. Field replacement procedures must follow the relay system shutdown and maintenance requirements defined for the installed configuration.

    Q: Which communication protocols can be processed through the UR4DH platform?
    A: The UR architecture supports IEC 61850, Modbus RTU/TCP, and DNP 3.0 communication protocols for protection, monitoring, and automation data exchange.

    Q: What environmental protection characteristics are specified for the UR4DH?
    A: The module is specified for operation from -40 deg C to +60 deg C with humidity conditions of 5% to 95% non-condensing. Dielectric and impulse withstand ratings are specified according to IEC 60255-5.

    Field Installation Guidelines

    Install the GE Multilin UR4DH module only in compatible GE Multilin Universal Relay chassis assemblies.

    Verify that the chassis power supply is isolated before module insertion or removal. Confirm connector alignment before engaging the module into the backplane interface to prevent mechanical or electrical damage.

    Use appropriate cabinet grounding practices for protection relay installations. Cable shields should be terminated according to the site grounding design to minimize electromagnetic interference. Maintain separation between communication wiring and high-voltage power conductors to reduce induced noise.

    Before commissioning, verify firmware compatibility, communication configuration parameters, relay addressing, and protective function mapping within the UR system configuration software.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama