Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX Transformer Protection Relay

GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX Transformer Protection Relay

Formulir produk

GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX Transformer Protection Relay The GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX, also cataloged as the T35 Transformer Protection Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: T35N03HCHF8FH6CM8FP6D06DWXX
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX Transformer Protection Relay

    The GE Multilin T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX, also cataloged as the T35 Transformer Protection Relay, operates as a dedicated hardware component for three-phase transformer differential protection within GE Universal Relay (UR) substation automation systems. The relay performs current acquisition, protection logic execution, event recording, and communication processing through modular I/O and network interfaces.

    Hardware Specifications

    Parameter Specification
    Model T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX
    Brand General Electric (GE Multilin)
    Origin GE Grid Solutions
    Dimensions 19-inch rack chassis, horizontal mount
    Operating Temp -20 deg C to +60 deg C
    Power Consumption Not specified in available documentation
    Product Series Universal Relay (UR) Family
    Base Function Transformer Protection System
    Power Supply High Voltage Power Supply, 125 / 250 VAC/DC
    CPU Module Standard CPU Module
    HMI Interface Enhanced graphical control panel with color LCD display
    CT/VT Configuration F8F: 8 CT / 4 VT inputs; H6C and M8F additional CT input modules
    Digital I/O P6D and 06D auxiliary input/output modules
    Communication Interface RS485, redundant Ethernet 100Base-FX / 10/100Base-T
    Protocol Support IEC 61850, Modbus RTU/TCP, DNP 3.0, IEEE 1588 PTP
    Recording Function Oscillography up to 64 samples per cycle; SOE record up to 1024 events

    Firmware, Network and I/O Architecture

    The GE Multilin T35 uses a modular hardware architecture with configurable CT/VT acquisition modules, digital input/output cards, and communication interfaces. The UR platform supports deterministic substation communication through IEC 61850 GOOSE messaging, client/server services, and redundant Ethernet network configurations including PRP, RSTP, and HSR.

    The relay firmware executes transformer protection algorithms including percentage differential protection (87T) with harmonic restraint, instantaneous differential protection (87P), restricted earth fault protection (87G), and transformer overexcitation supervision (24). The modular I/O structure allows channel expansion for multi-winding transformer applications and breaker current monitoring.

    Frequently Asked Questions

    Q: Does the T35 support hot-swap replacement of installed modules?
    A: Module replacement procedures must follow GE Multilin UR maintenance instructions. Hot-swap operation should not be assumed unless specifically supported by the installed hardware revision and firmware configuration.

    Q: What communication interfaces are available on the T35-N03-HCH-F8F-H6C-M8F-P6D-06D-WXX?
    A: The relay provides RS485 communication and redundant Ethernet interfaces supporting IEC 61850, Modbus RTU/TCP, DNP 3.0, and IEEE 1588 PTP synchronization.

    Q: How are transformer current inputs configured on this model?
    A: The specified configuration includes F8F, H6C, and M8F CT/VT modules for multiple current measurement channels used for transformer differential and protection functions.

    Field Installation Guidelines

    Install the relay in a compatible 19-inch rack enclosure with adequate mechanical support and grounding provisions. Verify CT polarity, phase identification, and secondary wiring before energizing protection inputs.

    Use shielded communication cables for RS485 and Ethernet connections where required by the installation environment. Terminate cable shields according to site grounding practices to reduce electromagnetic interference.

    Separate low-level communication wiring from high-current AC/DC power conductors. Confirm that CT circuits remain closed during maintenance operations and that all digital input/output wiring matches the configured protection logic.

    Verify firmware compatibility, module recognition, and protection settings after installation. Perform secondary injection testing before placing the transformer protection system into service.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun