Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin SR750-P5-G5-S5-HI-A20-G Feeder Protection Relay

GE Multilin SR750-P5-G5-S5-HI-A20-G Feeder Protection Relay

Formulir produk

GE Multilin SR750-P5-G5-S5-HI-A20-G Feeder Protection Relay Configured for feeder protection, monitoring, and control execution in GE Multilin 750 Feeder Management... Baca selengkapnya

SKU: SR750-P5-G5-S5-HI-A20-G
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin SR750-P5-G5-S5-HI-A20-G Feeder Protection Relay

    Configured for feeder protection, monitoring, and control execution in GE Multilin 750 Feeder Management Relay platforms, the GE Multilin SR750-P5-G5-S5-HI-A20-G (SR750 Feeder Protection Relay) provides direct physical and electrical execution for current sensing, breaker control, and power system diagnostics.

    Hardware Specifications

    Parameter Specification
    Model SR750-P5-G5-S5-HI-A20-G
    Brand GE Multilin
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Typical 15 W, Maximum 35 W
    Product Type Feeder Protection Relay
    Power Supply 88-300 VDC or 88-265 VAC, 45-66 Hz
    Phase Current Input 5 A CT secondary
    Ground Current Input 5 A CT secondary
    Sensitive Ground Input 5 A CT secondary
    Analog Outputs 8 assignable outputs, 0-20 mA or 4-20 mA DC
    Communication Interfaces Front RS232, Rear RS485 with Modbus RTU support
    Digital Inputs 16 assignable opto-isolated inputs
    Output Contacts Up to 8 Form A / Form C contacts
    Protection Functions 50/51 phase and ground overcurrent, 67 directional overcurrent, 27/59 voltage, 81 frequency, 50BF breaker failure, 49 thermal overload

    Firmware Flash Compatibility and Industrial Network Integration

    The SR750 platform uses programmable relay firmware with integrated FlexLogic control functions for custom protection and automation sequences. Firmware flash compatibility management defines the supported software environment for relay operation, configuration retention, and application updates.

    The relay supports industrial communication through RS232 and RS485 interfaces with Modbus RTU protocol. The communication structure allows exchange of protection status, metering values, event records, and control commands with supervisory systems.

    The hardware architecture provides current input processing for phase, ground, and sensitive ground protection channels. Waveform capture supports fault analysis with oscillography recording up to 32 samples per cycle, while the event recorder stores up to 256 time-tagged events.

    Frequently Asked Questions

    Q: Does the SR750-P5-G5-S5-HI-A20-G support hot-swap module replacement?
    A: The available technical data does not specify hot-swap operation. Module replacement should be performed with the relay de-energized and according to approved maintenance procedures.

    Q: What is the analog output load capability of the A20 option?
    A: The A20 option provides 8 assignable analog current outputs with selectable 0-20 mA or 4-20 mA DC operation and supports a maximum load of 600 ohms.

    Q: What environmental protection is provided by the G option?
    A: The G option applies factory conformal coating for harsh industrial environments and is specified for ISA S71.04 Class G3 conditions.

    Field Installation Guidelines

    Install the relay in a suitable protective enclosure with appropriate clearance for wiring access and maintenance activities.

    Connect CT secondary wiring using correct polarity and maintain separation between current circuits, control wiring, and communication cables. Shielded communication cables should follow standard industrial grounding practices to reduce electromagnetic interference.

    Verify control power wiring before energization. Confirm that the supply voltage range matches the HI power input specification of 88-300 VDC or 88-265 VAC.

    Route analog output wiring separately from high-current conductors. Use proper terminal tightening procedures and inspect all protective earth and enclosure bonding connections before commissioning.

    Configure protection settings, communication parameters, and FlexLogic sequences according to the approved system protection design before placing the relay into service.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun