Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C Generator Protection Relay

GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C Generator Protection Relay

Formulir produk

GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C Generator Protection Relay The GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C, also cataloged as the G60 Generator Protection Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: G60E00HCLF8FH6PM8FP6CU6CW6C
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C Generator Protection Relay

    The GE Multilin G60E00HCLF8FH6PM8FP6CU6CW6C, also cataloged as the G60 Generator Protection Relay, operates as a dedicated hardware component for generator protection signal processing and trip control within the GE Universal Relay (UR) Series platform.

    Hardware Specifications

    Parameter Specification
    Model G60E00HCLF8FH6PM8FP6CU6CW6C
    Brand GE Multilin
    Dimensions 19 in rack chassis, 19 in W x 8.75 in H x 9.38 in D
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Typically 25-40 W under full operational load
    Product Function Generator protection, control, metering, and monitoring relay
    Power Supply 110-250 VDC / 110-230 VAC high range or 24-48 VDC low range
    Current Inputs 1 A or 5 A nominal CT inputs
    Voltage Inputs 50-240 V AC nominal phase-to-neutral VT inputs
    Digital Inputs Opto-isolated configurable high-speed inputs
    Output Relays High-speed Form-C trip and control relays
    Communication Ports RS485, 100Base-FX fiber Ethernet, 100Base-T copper Ethernet
    Communication Protocols IEC 61850 Ed. 1 and Ed. 2, DNP3.0, Modbus RTU/TCP, IEC 60870-5-104
    Time Synchronization IEEE 1588 PTP, IRIG-B, SNTP
    Protection Functions 87G, 87T, 64G, 27TN, 40, 24, 46, 50/51, 21, 78, 32R/32F, 50BF
    Ingress Protection IP40 front panel, IP20 terminal blocks

    Industrial Relay Communication and Firmware Features

    The GE Multilin G60 uses the Universal Relay (UR) hardware architecture with modular communication and I/O expansion capability. The CPU module supports RS485 communication and redundant Ethernet interfaces for integration with protection networks and station automation systems.

    The relay supports IEC 61850 communication services, including Ethernet-based data exchange and time synchronization functions. Firmware flash compatibility allows controlled software maintenance within supported UR platform configurations.

    The modular slot structure supports I/O density scaling through CT/VT modules, digital input modules, and output relay modules. Backplane bus communication provides internal data exchange between protection processing, measurement, and interface modules.

    Frequently Asked Questions (FAQ)

    Q: Does the G60 support hot-swap replacement of hardware modules?
    A: The G60 uses a modular UR platform, but module replacement procedures must follow GE Multilin installation requirements. Hot-swap operation should not be assumed unless specifically supported by the installed hardware configuration.

    Q: What communication interfaces are available on the G60 relay?
    A: The relay supports RS485 communication, redundant 100Base-FX fiber Ethernet, 100Base-T copper Ethernet, and protocols including IEC 61850, DNP3.0, Modbus RTU/TCP, and IEC 60870-5-104.

    Q: What generator protection measurements are processed by the relay?
    A: The G60 processes CT current inputs, VT voltage inputs, digital status inputs, and protection logic signals for generator differential, ground fault, excitation, overcurrent, distance, reverse power, and breaker failure functions.

    Field Installation Guidelines

    Install the relay in a compatible 19 in rack enclosure with correct mechanical support and terminal access clearance. Verify power supply voltage range before energizing the unit.

    Terminate CT and VT wiring according to protection engineering drawings. Maintain separation between instrument transformer wiring, communication cables, and high-voltage conductors to reduce electromagnetic interference.

    Connect fiber Ethernet interfaces using approved optical components and maintain correct grounding practices for the chassis and protective earth connection. Cable shields should be terminated according to site grounding standards.

    Verify digital input polarity, output relay wiring, and trip circuit supervision connections before commissioning. Confirm firmware compatibility and configuration files before loading application settings into the relay.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun