Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E Multiple Feeder Protection System

GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E Multiple Feeder Protection System

Formulir produk

GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E Multiple Feeder Protection System The GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E, also cataloged as the F35 Multiple Feeder Protection System, operates as a... Baca selengkapnya

SKU: F35N03HCHTF8FH6EM8HP6EU8HW6E
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E Multiple Feeder Protection System

    The GE Multilin F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E, also cataloged as the F35 Multiple Feeder Protection System, operates as a dedicated hardware component for feeder protection, control, measurement, and communication within GE Multilin Universal Relay (UR) platforms.

    Hardware Specifications

    Parameter Specification
    Model F35-N03-HCH-TF8-FH6-EM8-HP6-EU8-HW6-E
    Brand GE Multilin
    Origin General Electric Universal Relay (UR) family
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Approximately 15-30 W nominal, up to 45 W depending on installed I/O modules
    Power Supply 125-250 V DC / 100-240 V AC nominal, operational range 88-300 V DC / 88-265 V AC
    Feeder Capacity Up to five feeders with busbar voltage measurement or up to six feeders without busbar voltage measurement
    Current Inputs 4 CT inputs, 1 A / 5 A selectable
    Voltage Inputs 4 VT inputs, 50-240 V AC nominal phase-to-neutral
    Communication Ports RS485, Ethernet interfaces (RJ45 or fiber depending on CPU option)
    Communication Protocols Modbus RTU, Modbus TCP/IP, DNP 3.0, IEC 61850 GOOSE/MMS optional
    Protection Functions 50P/51P, 50N/51N, 50G/51G, 49, 27/59, 81U/81O
    Environmental Coating Conformal coating for harsh environment operation

    Profinet / EtherNet-IP Deterministic Network and Firmware Compatibility

    The GE Multilin F35 uses a modular Universal Relay hardware structure with CPU-based processing, configurable I/O expansion, and communication interfaces. The relay architecture supports high-speed Ethernet communication functions through installed communication modules, enabling deterministic data exchange for protection monitoring, event reporting, and substation automation systems.

    The F35 firmware platform provides compatibility management for configured hardware modules, including CT/VT acquisition boards, digital I/O assemblies, and communication interfaces. Module configuration, FlexLogic programming, and firmware revision control define the operational behavior of the protection system.

    Frequently Asked Questions

    Q: Can the F35 support hot-swap replacement of installed modules?
    A: The F35 uses a modular architecture; however, module replacement procedures must follow GE Multilin maintenance requirements. Power isolation and configuration verification are required before removing or installing hardware assemblies.

    Q: What is the function of the CT/VT input modules in the F35 configuration?
    A: CT/VT modules provide analog current and voltage acquisition for feeder protection elements, metering calculations, fault recording, and protection algorithm execution.

    Q: Which communication protocols are available on the F35 relay?
    A: The F35 supports Modbus RTU, Modbus TCP/IP, DNP 3.0 serial/TCP communication, and optional IEC 61850 GOOSE and MMS functions depending on installed communication options.

    Field Installation Guidelines

    • Install the relay in a suitable protection panel with adequate mechanical support and environmental protection.
    • Route CT and VT wiring separately from high-energy power conductors to reduce electromagnetic interference.
    • Connect CT secondary circuits using correct polarity and approved shorting practices during maintenance activities.
    • Apply shielded communication cables where required and terminate shields according to site grounding standards.
    • Verify auxiliary supply voltage before energizing the relay. Confirm the installed power supply module matches the system voltage.
    • Check terminal tightness, module seating, and rear communication connections before commissioning.
    • Perform configuration verification after installation, including CT/VT ratios, digital input assignments, output relay logic, and communication addressing.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun