Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin 750 SR750 Feeder Management System

GE Multilin 750 SR750 Feeder Management System

Formulir produk

GE Multilin 750 SR750 Feeder Management System The GE Multilin 750 (SR750), also cataloged as the SR750 Feeder Management System, operates as a... Baca selengkapnya

SKU: SR750
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin 750 SR750 Feeder Management System

    The GE Multilin 750 (SR750), also cataloged as the SR750 Feeder Management System, operates as a dedicated hardware component for feeder protection, measurement, and control execution within electrical distribution protection networks. The unit provides digital processing of current, voltage, status inputs, and control outputs through a drawout relay platform.

    Hardware Specifications

    Parameter Specification
    Model 750 / SR750
    Brand GE Multilin (General Electric)
    Operating Temp -40 deg C to +60 deg C
    Series 700 Series Feeder Management System
    Control Power Supply HI Option: 88-300 VDC or 70-265 VAC; LO Option: 20-60 VDC or 20-48 VAC
    CT Inputs 1 A or 5 A phase CT inputs; 1 A or 5 A ground CT inputs
    VT Inputs 50 V to 240 V secondary inputs
    Digital Inputs Up to 12 programmable contact inputs
    Output Relays Up to 8 programmable output relays
    Analog I/O Optional 4-20 mA transducer inputs and outputs
    Communications RS232 front port, dual RS485 rear ports with Modbus RTU, optional Ethernet Modbus TCP

    Industrial Control Communication and Firmware Compatibility

    The GE Multilin 750 integrates programmable processing functions for feeder protection, metering, and control logic. The relay supports configurable I/O mapping, communication interfaces, and firmware-managed operating functions within the 700 Series platform. Communication architecture includes serial Modbus RTU connectivity through RS485 ports and optional Ethernet Modbus TCP integration for supervisory systems.

    Firmware flash compatibility is managed according to the relay hardware configuration and installed option set. Firmware updates require verification of hardware revision, communication configuration, and application settings before deployment.

    Frequently Asked Questions

    Q: Does the SR750 support hot-swap replacement during energized operation?

    A: The SR750 uses a drawout case design. Removal and insertion procedures must follow site electrical isolation requirements and the applicable protection system maintenance procedures.

    Q: What communication interfaces are available on the SR750?

    A: The unit provides an RS232 front communication port, dual RS485 rear communication ports supporting Modbus RTU, and optional Ethernet communication supporting Modbus TCP.

    Q: What current transformer inputs are supported by the relay?

    A: The SR750 accepts 1 A or 5 A secondary current transformer inputs for phase and ground protection measurement circuits.

    Field Installation Guidelines

    Install the relay in a compatible protection panel using the specified drawout mounting arrangement. Maintain separation between power wiring, CT/VT signal wiring, communication cables, and high-noise switching conductors.

    Terminate cable shields according to the site grounding design to reduce electromagnetic interference on measurement and communication circuits. Verify CT polarity, secondary wiring continuity, VT connection configuration, and control power polarity before energizing the unit.

    Confirm communication parameters including Modbus addressing, baud rate, and network settings before connection to supervisory or control systems. Record installed firmware revision and configuration data during commissioning.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun