Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin 750-P5-G1-S5-HI-A20-R-E-H Feeder Management Relay

GE Multilin 750-P5-G1-S5-HI-A20-R-E-H Feeder Management Relay

Formulir produk

GE Multilin 750-P5-G1-S5-HI-A20-R-E-H Feeder Management Relay The GE Multilin 750-P5-G1-S5-HI-A20-R-E-H, also cataloged as the 750 Feeder Management Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: 750-P5-G1-S5-HI-A20-R-E-H
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin 750-P5-G1-S5-HI-A20-R-E-H Feeder Management Relay

    The GE Multilin 750-P5-G1-S5-HI-A20-R-E-H, also cataloged as the 750 Feeder Management Relay, operates as a dedicated hardware component for feeder protection, current measurement, breaker control, and monitoring within GE Multilin 750/760 Protection System platforms.

    Hardware Specifications

    Parameter Specification
    Model 750-P5-G1-S5-HI-A20-R-E-H
    Brand GE Multilin
    Origin GE Multilin 750/760 Protection System Series
    Weight 14.00 lbs
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Not specified in available technical data
    Device Type Feeder Management Relay
    Control Power Supply 88-300 VDC or 70-265 VAC, 48-62 Hz
    Phase Current Input 5 A CT secondary
    Ground Current Input 5 A CT secondary zero-sequence input
    Sensitive Ground Input 5 A CT secondary
    Analog Outputs Eight assignable 4-20 mA DC outputs
    Display Interface Enhanced 40-character (2 x 20) backlit LCD with keypad navigation
    Communication Interfaces RS232, RS422/RS485, Ethernet
    Communication Protocols Modbus RTU, Modbus TCP/IP, DNP 3.0
    Enclosure Type Draw-out chassis with conformal coating option

    Industrial Control and Protection Integration

    The GE Multilin 750 series relay incorporates feeder monitoring functions through configurable current inputs, analog outputs, and digital communication interfaces. The 750-P5-G1-S5-HI-A20-R-E-H configuration supports 5 A phase current measurement, 5 A ground current sensing, and 5 A sensitive ground measurement channels for feeder protection schemes.

    The relay configuration supports SCADA and DCS data acquisition through Modbus RTU, Modbus TCP/IP, and DNP 3.0 communication protocols. The A20 option provides eight assignable 4-20 mA outputs for analog signal transmission to external monitoring systems.

    The relay hardware supports deterministic network communication requirements through Ethernet and serial communication ports. Firmware flash compatibility and configuration management are performed through the GE Multilin relay engineering environment for installed protection system maintenance.

    Frequently Asked Questions

    Q: What current input configuration is provided by the 750-P5-G1-S5-HI-A20-R-E-H model?
    A: The relay provides 5 A phase current inputs, 5 A ground current input, and 5 A sensitive ground current input according to the ordering configuration.

    Q: Does the relay support hot-swap replacement during feeder operation?
    A: The unit uses a draw-out chassis design. Removal or insertion procedures must follow site protection maintenance procedures and verify isolation conditions before servicing.

    Q: Which communication interfaces are available for system integration?
    A: The relay provides front RS232, RS422/RS485, and Ethernet communication interfaces supporting Modbus RTU, Modbus TCP/IP, and DNP 3.0 protocols.

    Field Installation Guidelines

    • Install the relay in a compatible protection panel or control cabinet with correct mechanical support for the draw-out chassis.
    • Verify CT secondary wiring polarity and terminal connections before energizing current inputs.
    • Maintain separation between CT wiring, control power wiring, and communication cables to reduce electromagnetic interference.
    • Apply cable shielding and grounding practices according to site electrical installation standards.
    • Confirm the control power supply range before connection: 88-300 VDC or 70-265 VAC at 48-62 Hz.
    • Check communication wiring termination for RS422/RS485 networks before commissioning.
    • Verify analog output loop wiring for correct polarity when connecting 4-20 mA channels to SCADA or DCS equipment.
    • Ensure conformal-coated units are installed according to environmental requirements for moisture and chemical exposure conditions.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun