GE Multilin 489-P5-LO-A20-E Generator Management Relay The GE Multilin 489-P5-LO-A20-E, also cataloged as the 489 Generator Management Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: 489-P5-LO-A20-E
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin 489-P5-LO-A20-E Generator Management Relay

    The GE Multilin 489-P5-LO-A20-E, also cataloged as the 489 Generator Management Relay, operates as a dedicated hardware component for generator protection, control, metering, and event monitoring within generator electrical protection systems. It provides 5 A CT input processing, 4-20 mA analog outputs, relay control functions, and serial communication interfaces.

    Hardware Specifications

    Parameter Specification
    Model 489-P5-LO-A20-E
    Brand GE Multilin
    Weight 10 lb
    Operating Temp -40 deg C to +60 deg C
    Power Consumption Maximum 45 VA AC / 30 W DC
    Product Type Generator Management Relay
    Control Power Supply 20-60 VDC or 20-48 VAC, 48-62 Hz
    Phase Current Inputs 5 A CT secondary inputs
    Analog Outputs 4 assignable 4-20 mA outputs, maximum 600 ohm load
    Output Contacts 6 relay contacts, 10 A continuous at 250 VAC / 30 VDC
    Frequency Sensing Range 20 to 70 Hz
    RTD Inputs 12 RTD inputs supporting platinum, nickel, and copper RTD types
    Communication Interface RS232 front port and RS485/RS422 rear port with Modbus RTU
    Mounting Type Panel mount draw-out construction
    Display Enhanced backlit LCD, 4 x 20 character format

    Deterministic Network and Firmware Compatibility Features

    The GE Multilin 489-P5-LO-A20-E integrates industrial control functions through programmable protection logic, serial communication channels, and configurable firmware parameters. The relay supports Modbus RTU communication through RS485/RS422 interfaces for data exchange with supervisory control systems. Firmware configuration supports protection setting management, event recording, metering functions, and relay logic execution within generator control architectures.

    The relay processes electrical measurement signals from CT and VT inputs for ANSI protection functions including overcurrent, voltage, frequency, reverse power, loss of excitation, thermal overload, unbalance protection, and generator differential protection. Configurable output assignments allow external control circuits to receive trip, alarm, and service status signals.

    Frequently Asked Questions

    Q: Does the 489-P5-LO-A20-E support hot-swap replacement during operation?
    A: The unit uses a draw-out construction for panel installation. Hot-swap operation is not specified in the provided technical data and should be evaluated according to the installed switchgear design.

    Q: What communication protocol is available on the rear communication port?
    A: The rear RS485/RS422 port supports Modbus RTU communication with selectable parity options including none, odd, and even.

    Q: What are the available analog output characteristics?
    A: The A20 option provides four assignable 4-20 mA analog outputs with a maximum load rating of 600 ohm.

    Field Installation Guidelines

    Install the relay in a suitable panel or switchgear enclosure using the specified draw-out mounting arrangement. Verify CT secondary wiring polarity and terminal routing before energizing the unit.

    Use shielded wiring for analog signal circuits where required by the installation environment. Terminate cable shields according to the site grounding standard and avoid routing low-level measurement wiring together with high-current power conductors.

    Confirm control power voltage compatibility before connection. Check RS485/RS422 communication wiring polarity, termination requirements, and isolation practices to maintain stable serial communication performance.

    Verify VT, CT, RTD, and relay output wiring against the application protection scheme before commissioning. Configure protection settings and communication parameters using compatible GE Multilin configuration software.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun