Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin 369-HI-R-0-0-0-E Motor Management Relay

GE Multilin 369-HI-R-0-0-0-E Motor Management Relay

Formulir produk

GE Multilin 369-HI-R-0-0-0-E Motor Management Relay The GE Multilin 369-HI-R-0-0-0-E, also cataloged as the 369 Motor Protection Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: 369-HI-R-0-0-0-E
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin 369-HI-R-0-0-0-E Motor Management Relay

    The GE Multilin 369-HI-R-0-0-0-E, also cataloged as the 369 Motor Protection Relay, operates as a dedicated hardware component for three-phase motor protection, thermal monitoring, and electrical fault execution within industrial power control networks.

    Hardware Specifications

    Parameter Specification
    Model 369-HI-R-0-0-0-E
    Brand GE Multilin
    Operating Temp -40 deg C to +60 deg C
    Power Consumption 10-20 W nominal, maximum 35 VA
    Product Type Motor Management Relay
    Control Voltage 90-300 VDC / 70-265 VAC, 50/60 Hz
    Current Inputs 1 A / 5 A CT inputs, software configurable
    Ground Current Input 1 A / 5 A CT or 50:0.025 zero-sequence CT input
    Digital Inputs 4 optically isolated dry contact inputs
    Output Relays 4 relay outputs: Trip, Alarm, Auxiliary 1, Auxiliary 2
    Contact Rating 10 A continuous, 30 A make for 0.2 s at 250 VAC / 30 VDC
    Communication Ports Dual RS485 rear ports
    Communication Protocol Modbus RTU
    Baud Rate 1,200 to 19,200 bps
    Environmental Coating Conformal coating for corrosive gas, moisture, and dust protection

    Firmware and Industrial Network Integration

    The GE Multilin 369-HI-R-0-0-0-E supports deterministic serial communication through dual RS485 interfaces configured for redundant Modbus RTU connectivity. The relay exchanges motor protection status, metering values, event records, and diagnostic information with PLC, SCADA, and supervisory control systems.

    The relay firmware provides configurable motor protection functions including thermal overload, short circuit, phase unbalance, undercurrent, mechanical jam detection, ground fault monitoring, and frequent start protection. Firmware compatibility shall be verified against the installed relay revision before replacement or configuration transfer.

    Thermal modeling calculates motor thermal capacity utilization through current measurement, cooling rate parameters, and RTD feedback inputs where applicable. The stored event and fault recording functions capture trip conditions, alarms, and oscillography data for electrical fault analysis.

    Frequently Asked Questions

    Q: Does the GE Multilin 369-HI-R-0-0-0-E support hot-swap replacement?
    A: The relay is not specified as a hot-swappable device. Replacement should be performed with control power removed and field wiring isolated according to electrical maintenance procedures.

    Q: What communication interface is available for PLC or SCADA connection?
    A: The relay provides two rear RS485 communication ports supporting Modbus RTU protocol for serial network integration.

    Q: What type of motor current measurement inputs are supported?
    A: The relay accepts standard 1 A or 5 A CT secondary inputs with software configuration, including ground current measurement through compatible CT configurations.

    Field Installation Guidelines

    Install the relay in a protected control cabinet with appropriate environmental separation from high-voltage switching equipment. Verify CT polarity, phase sequence, and secondary wiring before energization.

    Use shielded communication cable for RS485 connections and terminate the shield according to the site grounding practice. Maintain separation between communication wiring, CT circuits, and high-current conductors to reduce electrical interference.

    Confirm that the control voltage supply matches the specified AC/DC input range before connection. Ensure all protective earth and cabinet grounding points maintain low-impedance bonding.

    Before commissioning, verify motor protection settings, CT ratios, digital input states, relay output assignments, and Modbus communication parameters through the configuration interface.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun