Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE Multilin 369-HI-0-0-0-0-0-E Motor Protection Relay

GE Multilin 369-HI-0-0-0-0-0-E Motor Protection Relay

Formulir produk

GE Multilin 369-HI-0-0-0-0-0-E Motor Protection Relay The GE Multilin 369-HI-0-0-0-0-0-E, also cataloged as the 369 Motor Protection Relay, operates as a dedicated hardware... Baca selengkapnya

SKU: 369-HI-0-0-0-0-0-E
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE Multilin 369-HI-0-0-0-0-0-E Motor Protection Relay

    The GE Multilin 369-HI-0-0-0-0-0-E, also cataloged as the 369 Motor Protection Relay, operates as a dedicated hardware component for three-phase motor protection, monitoring, and control signal processing within GE Multilin motor management systems.

    Hardware Specifications

    Parameter Specification
    Model 369-HI-0-0-0-0-0-E
    Brand GE Multilin
    Origin USA
    Weight 3.6 kg
    Dimensions 280 mm x 110 mm x 205 mm
    Operating Temp -25 deg C to +60 deg C
    Power Consumption Nominal 10 W, maximum 20 W
    Product Type Motor Protection Relay
    Control Power 50-300 VDC or 60-265 VAC, 50/60 Hz
    Current Inputs 1 A or 5 A phase CT inputs, programmable
    Ground CT Input 1 A, 5 A, or 50:0.025 core balance CT
    Frequency Tracking 20 Hz to 70 Hz
    Output Relays 4 output relays: Trip, Alarm, Auxiliary 1, Auxiliary 2
    Communication Ports Front RS232 and rear RS485 Modbus RTU
    Analog Output One programmable 4-20 mA or 0-1 mA output
    Display 40-character 2 x 20 display with 14-key keypad
    Diagnostics Option Enhanced faceplate, LED indicators, Motor Health Report, Start Data Logger

    Firmware Flash Compatibility and Industrial Control Communication

    The GE Multilin 369-HI-0-0-0-0-0-E integrates firmware-based protection logic for motor operating state evaluation, event recording, and configuration management. Firmware flash compatibility is maintained through supported GE Multilin configuration tools and device firmware procedures.

    The relay processes current measurement inputs, thermal model calculations, and programmable protection parameters to execute functions including overload protection (ANSI 49/51), locked rotor detection, phase unbalance monitoring, ground fault protection, and loss of load detection.

    The communication interface provides configuration and data access through RS232 and RS485 links. Modbus RTU communication supports integration with industrial control networks for relay status, measurement values, event records, and parameter exchange.

    Frequently Asked Questions (FAQ)

    Q: Does the 369-HI-0-0-0-0-0-E support hot-swap replacement during operation?
    A: No. The relay uses a fixed panel-mount enclosure and requires power isolation before removal, wiring changes, or hardware replacement.

    Q: What current transformer inputs are supported by the relay?
    A: The relay accepts programmable 1 A or 5 A phase CT secondary inputs and supports selectable ground CT configurations.

    Q: How is configuration data transferred to the relay?
    A: Configuration and monitoring data are transferred through the front RS232 interface or rear RS485 Modbus RTU communication connection using compatible configuration software.

    Field Installation Guidelines

    Install the GE Multilin 369-HI-0-0-0-0-0-E in a protected panel enclosure with adequate clearance for wiring access and heat dissipation.

    Use shielded signal cables for communication and analog output wiring where required by the installation environment. Connect cable shields according to the site grounding practice to reduce electrical interference.

    Route CT wiring separately from high-voltage power conductors to reduce induced noise. Verify CT polarity, secondary connections, and grounding before energizing the motor protection circuit.

    Confirm the control voltage selection matches the installed supply source before applying power. Perform parameter verification, input signal validation, and relay output testing during commissioning.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun