GE IS230STCIH6A Simplex Thermocouple Input Terminal Board The GE IS230STCIH6A, also cataloged as the IS230STCIH6A Simplex Thermocouple Input Terminal Board, operates as a... Baca selengkapnya

SKU: IS230STCIH6A
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE IS230STCIH6A Simplex Thermocouple Input Terminal Board

    The GE IS230STCIH6A, also cataloged as the IS230STCIH6A Simplex Thermocouple Input Terminal Board, operates as a dedicated hardware component for thermocouple temperature signal acquisition within GE Mark VIe Speedtronic control systems. The board provides conditioned analog temperature inputs from field sensors to turbine controller processing channels.

    Hardware Specifications

    Parameter Specification
    Model IS230STCIH6A
    Brand GE
    Origin United States
    Weight 0.5 kg
    Operating Temp -30 deg C to +65 deg C
    Power Consumption Not specified
    Series Mark VIe Speedtronic Control System
    Product Type Simplex Thermocouple Input Terminal Boards
    Input Channels 12 thermocouple input channels
    Supported Thermocouple Types Type E, J, K, S, T
    Signal Conditioning EMI filtering, linearization, and scaling
    Cold Junction Compensation Integrated CJC circuitry
    Isolation Channel-to-channel and channel-to-ground isolation
    Terminal Interface Barrier terminal strips for thermocouple wiring
    Storage Temperature -40 deg C to +85 deg C
    Humidity Range 5% to 95% non-condensing
    Mounting Standard Mark VIe rack slot
    Compliance IEC 60584 thermocouple standard

    Industrial Control Signal Processing and I/O Density Scaling

    The IS230STCIH6A provides thermocouple signal termination and conditioning functions within the GE Mark VIe control architecture. The board receives temperature signals from field thermocouples, applies cold junction compensation, linearization, and filtering, then transfers processed input data through the Mark VIe I/O interface.

    The terminal board supports I/O density scaling by integrating 12 temperature measurement channels into a simplex hardware assembly. Firmware flash compatibility depends on the installed GE Mark VIe controller, I/O pack configuration, and system revision.

    Channel isolation separates thermocouple measurement circuits from adjacent electrical paths, reducing signal interference during temperature acquisition. The input processing design supports deterministic temperature feedback collection for turbine monitoring and protection logic.

    Frequently Asked Questions

    Q: How many thermocouple inputs are available on the IS230STCIH6A?
    A: The IS230STCIH6A provides 12 thermocouple input channels in simplex configuration.

    Q: Which thermocouple types are supported by the board?
    A: The board supports Type E, J, K, S, and T thermocouple sensors.

    Q: What function does the CJC circuit perform on the IS230STCIH6A?
    A: The cold junction compensation circuit corrects reference junction effects during thermocouple temperature measurement processing.

    Field Installation Guidelines

    Install the IS230STCIH6A in the specified GE Mark VIe rack position and confirm connector engagement before applying system power.

    Use compatible thermocouple extension cables and maintain correct polarity between field sensors and terminal connections. Route thermocouple wiring separately from high-current conductors, switching devices, and power supply cables to reduce electromagnetic interference.

    Connect cable shields according to cabinet grounding practices. Verify terminal assignments, sensor types, and channel configuration before commissioning.

    Inspect terminal blocks, field wiring insulation, and connector conditions during maintenance activities. Avoid unnecessary cable loops and maintain separation between temperature measurement circuits and electrical noise sources.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun