Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE IS200JPDSG1ACB Power Distribution Board

GE IS200JPDSG1ACB Power Distribution Board

Formulir produk

GE IS200JPDSG1ACB Power Distribution Board The GE IS200JPDSG1ACB, also cataloged as the IS200JPDSG1ACB Power Distribution Board, operates as a dedicated hardware component for... Baca selengkapnya

SKU: IS200JPDSG1ACB
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE IS200JPDSG1ACB Power Distribution Board

    The GE IS200JPDSG1ACB, also cataloged as the IS200JPDSG1ACB Power Distribution Board, operates as a dedicated hardware component for regulated DC power distribution within the GE Mark VI turbine control system. It provides protected voltage routing to controller, exciter, and I/O subsystem assemblies through board-level power circuits.

    Hardware Specifications

    Parameter Specification
    Model IS200JPDSG1ACB
    Brand GE
    Origin United States of America (USA)
    Weight 0.9 kg
    Dimensions 16.51 cm x 17.8 cm x 2 cm
    Operating Temp -30 to +65 deg C
    Power Consumption Up to 250 W total power distribution capacity
    Product Type Power Distribution Board
    Series Mark VI Turbine Control / Excitation Systems
    Input Voltage 125 VDC nominal
    Output Voltages 5 VDC, 15 VDC, 24 VDC regulated outputs
    Protection Fuses, surge suppression, overvoltage protection
    Isolation 2500 Vrms channel-to-ground
    PCB Treatment Conformal coating, ACB revision
    Connectors Backplane and ribbon cable connectors
    Agency Approval Class 1 Division 2 explosive atmosphere

    Industrial Control Power Distribution Characteristics

    The IS200JPDSG1ACB applies GE Mark VI power distribution architecture for multi-voltage DC supply routing. The board provides regulated output paths for control electronics and exciter-related assemblies while maintaining electrical separation through protected distribution circuits.

    The JPDS board supports backplane-based power delivery and uses conformal coating to reduce exposure effects from moisture, dust, and industrial contaminants. Surge suppression and fuse protection circuits provide fault isolation at the board level.

    The board integrates within GE deterministic turbine control networks where stable DC power availability supports controller communication, I/O density scaling, and firmware-controlled hardware operation. Power distribution interfaces must match the configured Mark VI rack arrangement and connected modules.

    Frequently Asked Questions

    Q: What voltage inputs and outputs are supported by the IS200JPDSG1ACB?
    A: The board accepts 125 VDC nominal input and provides regulated 5 VDC, 15 VDC, and 24 VDC distribution outputs for compatible Mark VI control assemblies.

    Q: Does the IS200JPDSG1ACB provide electrical isolation?
    A: Yes. The board specification includes 2500 Vrms channel-to-ground isolation for power distribution protection.

    Q: What installation conditions are required for this power distribution board?
    A: The board requires correct rack alignment, proper backplane connection, grounding, and shielding practices to maintain power integrity and reduce EMI effects.

    Field Installation Guidelines

    Install the IS200JPDSG1ACB into the designated GE Mark VI rack position and verify mechanical alignment before securing the board assembly. Confirm that input and output power connections match the system wiring documentation.

    Connect grounding conductors according to the control cabinet grounding scheme. Maintain separation between power wiring and low-level signal cables to reduce electrical interference. Use shield termination practices appropriate for turbine control installations.

    Before energizing the rack, verify fuse conditions, connector seating, and DC supply polarity. Replacement or maintenance work should be performed with the rack de-energized unless the system documentation specifically permits live maintenance procedures.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun