GE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module

GE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module

Formulir produk

GE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module Configured for actuator control execution and redundant power interface management in... Baca selengkapnya

SKU: IS200AEPAH1AFD
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE IS200AEPAH1AFD Auxiliary Control and Redundant Power Supply Module

    Configured for actuator control execution and redundant power interface management in GE Mark VI/Mark VIe turbine control platforms, the GE IS200AEPAH1AFD (IS200AEPAH1AFD Auxiliary Control Module) provides direct physical/electrical execution. The module processes actuator feedback signals, controls output channels, and distributes regulated power rails within the VME-based control architecture.

    Hardware Specifications

    Parameter Specification
    Model IS200AEPAH1AFD
    Brand GE
    Origin USA
    Type Auxiliary Control / Redundant Power Supply Module
    System Platform GE Mark VI / Mark VIe Speedtronic turbine control system
    Input Voltage 85-132 VAC / 170-265 VAC auto-ranging or 110-150 VDC
    Output Voltages +5 VDC, +/-15 VDC, +24 VDC
    Output Power Rating 200-250 W
    Processor 32-bit processor, 160 MHz, watchdog timer
    Actuator Outputs 2 channels, selectable 4-20 mA or +/-10 V
    Position Feedback Inputs 2 LVDT inputs, 2 potentiometer inputs
    Output Resolution 14-bit, 0.006% of full scale
    Update Rate 4 kHz per channel
    Response Time 1 ms feedback-to-output
    Redundancy Support Simplex, dual, and triple configurations
    Weight 0.6 kg
    Dimensions 25 x 18 x 2.5 cm
    Operating Temp -40 to +70 deg C
    Power Consumption Not specified; module output rating 200-250 W
    Mounting VME rack slot insertion
    Protection Functions Overvoltage, overcurrent, short-circuit, thermal shutdown

    GE Mark VIe Control and Power Interface Characteristics

    The IS200AEPAH1AFD module uses industrial control architecture features associated with GE Mark VI/Mark VIe systems, including deterministic control processing, actuator feedback handling, and redundant power distribution. The module supports I/O density scaling through multiple feedback and output channels while maintaining separated signal paths for actuator regulation.

    The board provides interfaces for LVDT and potentiometer position feedback, with actuator command outputs configurable for current or voltage operation. The onboard watchdog timer monitors processor operation, while protection circuits supervise power and output conditions.

    Frequently Asked Questions

    Q: What actuator signals are supported by the IS200AEPAH1AFD module?
    A: The module supports two actuator output channels configurable for 4-20 mA or +/-10 V signals and accepts position feedback from LVDT and potentiometer inputs.

    Q: Does the module support redundant power configurations?
    A: The IS200AEPAH1AFD supports simplex, dual, and triple redundancy configurations within compatible Mark VI/Mark VIe control architectures.

    Q: What type of rack installation is required?
    A: The module is installed through a VME rack slot interface and requires proper chassis alignment and connector engagement.

    Field Installation Guidelines

    Install the module in the designated VME rack position with the chassis power removed before insertion or removal. Verify connector seating and mechanical retention before applying system power.

    Route actuator signal wiring separately from high-current power conductors to reduce electrical interference. Use appropriate shielding practices for analog feedback cables, with shield termination following the system grounding design.

    Verify input voltage configuration before energizing the module. Confirm actuator feedback polarity, signal scaling, and output channel assignment during commissioning.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun