GE DS200TCCBG1BED Common Extended Analog I/O Board
The GE DS200TCCBG1BED, also cataloged as the DS200TCCB Common Extended Analog I/O Board, operates as a dedicated hardware component for analog signal acquisition and conversion within the GE Speedtronic Mark V turbine control system. The board processes RTD, thermocouple, transmitter, and voltage input signals through integrated A/D conversion and analog output channels.
Hardware Specifications
Parameter
Specification
Model
DS200TCCBG1BED
Brand
GE
Origin
USA
Weight
2.00 lbs
Dimensions
230 x 170 x 30 mm
Operating Temp
0 deg C to +50 deg C typical; extended tolerance -30 deg C to +65 deg C
The DS200TCCBG1BED extends the analog processing capacity of the GE Mark V platform through additional RTD, thermocouple, current, and voltage measurement channels. The onboard signal conditioning circuitry performs local conversion of field analog signals before transferring processed data through the control architecture.
The board uses GE industrial control I/O density scaling methods to increase sensor channel availability while maintaining compatibility with Mark V control racks. The onboard Intel 80196 microcontroller manages local scanning, conversion handling, and diagnostic processing.
Frequently Asked Questions
Q: What types of field signals can be connected to the DS200TCCBG1BED analog inputs? A: The board supports differential analog inputs for RTD, thermocouple, 4-20 mA transmitter signals, and +/-10 V voltage inputs.
Q: Does the DS200TCCBG1BED provide isolation between field wiring and control electronics? A: Yes. The board provides 1500 V field-to-logic isolation for separation between external analog signals and internal control circuits.
Q: Is firmware stored directly on the board hardware? A: Yes. The board uses socketed EPROM devices for firmware storage and calibration data management.
Field Installation Guidelines
Install the DS200TCCBG1BED in the designated GE Speedtronic Mark V rack location and verify connector identification before applying power. Confirm that JCC, JDD, JEE, and 3PL connections match the approved wiring documentation.
Analog signal cables should be routed separately from high-voltage and high-current conductors to reduce electromagnetic interference. Shielded instrumentation cables should be used where required, with cable shields terminated according to the control cabinet grounding design.
After installation, verify field input polarity, RTD and thermocouple wiring configuration, and analog channel assignments. Perform the required calibration procedure using the onboard reference points before returning the turbine control system to service.