GE DS200TCCBG1B Mark V Series Extended Analog I/O Board

GE DS200TCCBG1B Mark V Series Extended Analog I/O Board

Formulir produk

GE DS200TCCBG1B Mark V Series Extended Analog I/O Board The GE DS200TCCBG1B, also cataloged as the DS200TCCB Extended Analog I/O Board, operates as... Baca selengkapnya

SKU: DS200TCCBG1B
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE DS200TCCBG1B Mark V Series Extended Analog I/O Board

    The GE DS200TCCBG1B, also cataloged as the DS200TCCB Extended Analog I/O Board, operates as a dedicated hardware component for analog signal conditioning and acquisition within Mark V Speedtronic turbine control system platforms.

    Hardware Specifications

    Parameter Specification
    Model DS200TCCBG1B
    Brand GE
    Origin USA
    Weight 0.45 kg
    Operating Temp -30 to +65 deg C
    Power Consumption 150 mA @ 5 VDC
    Board Type Extended Analog I/O Board (TCCB)
    Onboard Microcontroller Intel 80196
    Supported Inputs 4-20 mA, 0-1 mA, RTD (Pt100/Pt1000), low-voltage analog
    Resolution 12-bit A/D conversion
    Board Connectors Dual 50-pin IDC connectors (JCC, JDD)
    Communication Interface Proprietary Mark V parallel backplane bus
    Galvanic Isolation 707 VDC channel-to-backplane isolation
    Relative Humidity 5-95% RH, non-condensing

    Deterministic Backplane Communication and Channel-to-Channel Isolation

    The board leverages an onboard Intel 80196 microcontroller to execute hardware-level signal conditioning, digital filtering, and sensor linearization directly at the acquisition node. High-density parallel backplane bus communication velocity allows deterministic data transfer to the primary processing core without imposing processing overhead on the central controller. To prevent ground loops in complex field wiring topologies, the module incorporates 707 VDC channel-to-backplane galvanic isolation, ensuring signal integrity across high-noise industrial environments and maintaining signal scaling stability for critical control loops.

    Frequently Asked Questions

    Q: What precautions must be taken regarding power removal prior to replacing the DS200TCCBG1B board?

    A: The DS200TCCBG1B does not support active hot-swapping. Complete power removal from the R5 core rack and de-energization of all field I/O loop power supplies must be verified prior to removing or inserting the board to prevent backplane damage and sensor surge current spikes.

    Q: How are onboard calibration settings and firmware revisions preserved during board replacement?

    A: Calibration parameters and operational firmware reside within socketed PROM modules onboard the board. When replacing a unit, the original PROM chips must be swapped to the new board hardware or the system memory reconfigured via Mark V diagnostic tools to maintain control calibration parity.

    Field Installation Guidelines

    Proper handling and mounting procedures are critical to ensuring continuous operation of the DS200TCCBG1B module:

    1. ESD Grounding Standards: Always wear a grounded wrist strap connected to the cabinet frame ground before removing the board from its anti-static shielding enclosure.
    2. Mechanical Fastening: Slide the board card-edges smoothly into the designated slot inside the Mark V R5 cabinet enclosure. Ensure all retention screws are fully tightened to secure board grounding chassis paths.
    3. Cable Routing and Strain Relief: Connect the dual 50-pin IDC ribbon connectors (JCC and JDD) securely to their respective pin headers. Ensure ribbon cables are seated square without applying side-tension to the connector pins.
    4. Shield Termination: Terminate all field analog cable shielding at the single-point cabinet ground bar using bare metal clamps. Do not ground instrument cable shields at both ends to prevent circulating ground currents across analog channels

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun