GE DS200TBQCG1A Analog Input / Milliamp I/O Termination Module

GE DS200TBQCG1A Analog Input / Milliamp I/O Termination Module

Formulir produk

GE DS200TBQCG1A Analog Input / Milliamp I/O Termination Module Configured for analog signal acquisition, conditioning, and field termination in the... Baca selengkapnya

SKU: DS200TBQCG1A
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE DS200TBQCG1A Analog Input / Milliamp I/O Termination Module

    Configured for analog signal acquisition, conditioning, and field termination in the Mark V Speedtronic turbine control system, the GE DS200TBQCG1A (DS200TBQC Analog Input / Milliamp I/O Termination Module) provides direct electrical interface between field devices and the TCQA board installed within the RST control cores. The DS200TBQCG1A supports 4-20 mA signal routing, LVDT/R position inputs, and configurable milliamp output channels through dedicated terminal and connector assemblies.

    Suffix Breakdown & Model Matrix

    The available revision variants identify hardware revision levels rather than different functional products.

    Model Description
    DS200TBQCG1A Base Analog Input / Milliamp I/O Termination Module
    DS200TBQCG1AAA Hardware revision variant
    DS200TBQCG1ABB Hardware revision variant

    Hardware Specifications

    Parameter Specification
    Model DS200TBQCG1A
    Brand GE General Electric
    Origin United States
    Product Type Analog Input / Milliamp I/O Termination Module
    Series Mark V Speedtronic (DS200)
    Functional Description RST Analog Termination Board
    Functional Acronym TBQC
    Installation Location RST cores (R1, R2, R3), Position 9
    Interface Board TCQA Board
    Analog Inputs 4-20 mA input channels
    Position Inputs LVDT/R position inputs
    Analog Outputs Configurable 20 mA or 200 mA output range
    Terminal Blocks 2 terminal blocks (TB1, TB2), 166 total terminals
    Connectors 3 x 40-pin, 3 x 34-pin, 1 x TEST port
    Jumper Configuration BJ1-BJ17 hardware jumpers
    PCB Coating Normal Coating
    Operating Temp -20 deg C to +60 deg C
    Protection Rating IP20
    Weight Approximately 0.35 kg to 0.75 kg
    Power Consumption Not specified by manufacturer

    Backplane Communication and Firmware Compatibility

    The module exchanges field I/O signals with the associated TCQA board through dedicated multi-pin connectors installed within the Mark V backplane architecture. JBR transfers 4-20 mA input and output current signals, while JFR carries LVDT/R position signals. Auxiliary headers (JBS, JBT, JFS, and JFT) are reserved for system expansion or background functions. Hardware jumpers provide local channel configuration without altering application firmware. Compatibility should be verified against the installed Mark V hardware revision before replacement.

    Frequently Asked Questions

    Q: Does the DS200TBQCG1A support hot-swapping during turbine operation?
    A: The supplied documentation does not specify hot-swap capability. Installation or replacement should follow the controller maintenance procedure with power removed from the affected hardware.

    Q: What is the purpose of jumpers BJ16 and BJ17?
    A: BJ16 and BJ17 select the maximum output current range for the two milliamp output channels, allowing configuration for either 20 mA or 200 mA operation.

    Q: What is the function of the TEST connector?
    A: The TEST port provides a diagnostic connection for field measurement and maintenance activities using appropriate test instruments.

    Field Installation Guidelines

    • Verify that the module is installed in the designated RST core position before connecting field wiring.
    • Label conductors according to the TB1 and TB2 terminal numbering to maintain traceability during maintenance.
    • Route analog signal wiring separately from high-voltage or high-current conductors to reduce electrical interference.
    • Terminate cable shields according to the control cabinet grounding practice and avoid multiple shield ground points unless specified by the system design.
    • Confirm jumper positions before energizing the system, particularly BJ16 and BJ17 when configuring output current ranges.
    • Inspect all multi-pin connectors for complete engagement before returning the controller to service.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama