Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

GE DS200TBCAG1A Analog Terminal Board

GE DS200TBCAG1A Analog Terminal Board

Formulir produk

GE DS200TBCAG1A Analog Terminal Board Configured for analog signal termination and field wiring interface functions in the GE Mark V... Baca selengkapnya

SKU: DS200TBCAG1A
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    GE DS200TBCAG1A Analog Terminal Board

    Configured for analog signal termination and field wiring interface functions in the GE Mark V Speedtronic Control System, the GE DS200TBCAG1A (DS200TBCAG1A Analog Terminal Board) provides direct physical/electrical execution between field transmitters, transducers, and turbine control processors.

    Hardware Specifications

    Parameter Specification
    Model DS200TBCAG1A
    Brand General Electric (GE)
    Origin United States
    Product Type Analog Terminal Board / Termination Module
    System Series Mark V Speedtronic Control System
    Functional Revision Revision A
    Signal Compatibility Analog Inputs / Analog Outputs, 4-20 mA, 0-10 V, transducer signals
    Terminal Connections Barrier terminal blocks with screw terminals
    Onboard Connectors Multi-pin ribbon cable connectors, including 26-pin / 50-pin header interfaces
    Mounting Type Direct chassis mount / Mark V control cabinet assembly
    Operating Temp -30 deg C to +65 deg C
    Power Consumption Passive termination interface; no independent field power supply required
    Storage Temp -40 deg C to +85 deg C
    Relative Humidity 5% to 95%, non-condensing

    GE Mark V Analog Signal Termination Characteristics

    The DS200TBCAG1A is configured for analog field signal termination within the Mark V Speedtronic architecture. The board routes incoming transmitter and sensor signals through barrier terminal blocks and transfers conditioned analog channels to the control processor interface through ribbon cable connections.

    The terminal assembly supports signal separation, field wiring organization, and noise reduction practices required for turbine control instrumentation circuits. Proper shield termination and cable routing are required to maintain analog measurement accuracy in electrically active environments.

    The board architecture follows GE industrial control hardware design practices, including backplane interface compatibility and firmware-independent signal termination functionality.

    Frequently Asked Questions

    Q: Does the DS200TBCAG1A provide signal processing functions?
    A: No. The DS200TBCAG1A functions as an analog termination and interface board. Signal processing is performed by associated Mark V control modules.

    Q: What field signals can be connected to this terminal board?
    A: The board interfaces with analog field signals including 4-20 mA current loops, 0-10 V voltage signals, and compatible transducer outputs as defined by the Mark V system configuration.

    Q: Are ribbon cable connections required for operation?
    A: Yes. The board uses multi-pin ribbon cable interfaces to transfer terminated analog channels between the terminal assembly and connected Mark V control hardware.

    Field Installation Guidelines

    • Install the DS200TBCAG1A within the designated Mark V control cabinet chassis location according to system drawings.
    • Verify terminal assignments before connecting field instruments to prevent incorrect analog channel mapping.
    • Use shielded instrumentation cable for low-level analog signals and connect cable shields according to site grounding practices.
    • Separate analog signal wiring from high-current power conductors and switching circuits to reduce electrical interference.
    • Confirm ribbon cable orientation and connector seating before system energization.
    • Inspect terminal screws, cable strain relief points, and connector contacts during maintenance activities.
    • Follow GE Mark V cabinet documentation for module replacement, wiring verification, and system commissioning procedures.

    Spesifikasi

    • Merek: General Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun