Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Fieldbus Monitor Module | 1701/15 141379-01 | Bently Nevada

Fieldbus Monitor Module | 1701/15 141379-01 | Bently Nevada

Formulir produk

Bently Nevada 1701/15 Fieldbus Monitor Module The Bently Nevada 1701/15, also cataloged as the 1701 Fieldbus Monitor Module, operates as... Baca selengkapnya

SKU: 1701/15 141379-01
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 1701/15 Fieldbus Monitor Module

    The Bently Nevada 1701/15, also cataloged as the 1701 Fieldbus Monitor Module, operates as a dedicated hardware component for interfacing machinery protection systems with Foundation Fieldbus and Profibus digital networks within industrial monitoring racks.

    Hardware Specifications

    Parameter Specification
    Model 1701/15 (Part No. 141379-01)
    Brand Bently Nevada
    Origin USA
    Weight 0.2kg
    Dimensions Single-slot width for 1701 series rack
    Operating Temp -30 deg C to +65 deg C
    Storage Temp -40 deg C to +85 deg C
    Humidity 95 % non-condensing max
    Power Consumption Low-power, supplied via rack backplane
    Protocol Support Foundation Fieldbus / Profibus PA/DP
    Data Transfer Rate Auto-baud or fixed per protocol specification
    Hazardous Area Approvals ATEX, IECEx, CSA for Zone 2 / Class I, Div 2

    Eddy-Current Probe Scaling and Signal Integrity

    The module maintains strict eddy-current probe scaling accuracy by aligning transducer output with calibrated gap voltage targets of -10 VDC. This ensures rotor dynamics measurements remain consistent under varying proximity probe conditions. Cross-talk suppression circuitry minimizes interference between adjacent channels, preserving fidelity in vibration and position datasets transmitted over the fieldbus.

    Frequently Asked Questions

    Q: Can the 1701/15 be hot-swapped without interrupting rack operation?

    A: Hot-swapping is not recommended unless the rack firmware explicitly supports it; always verify compatibility before removal.

    Q: Does the module require separate power wiring for the fieldbus side?

    A: No. Power is derived from the rack backplane, with galvanic isolation preventing ground loops between fieldbus and internal logic circuits.

    Field Installation Guidelines

    Install the module in a properly grounded 1701 series rack enclosure. Ensure shield terminations are connected to the rack’s designated earth bar to maintain signal integrity. Maintain separation between fieldbus cabling and high-voltage power wiring to reduce electromagnetic interference. Verify firmware revision compatibility prior to installation to prevent communication faults.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama