Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

FC-IOTA-R24 | Honeywell | Redundant IO Termination Assembly

FC-IOTA-R24 | Honeywell | Redundant IO Termination Assembly

Formulir produk

Honeywell FC-IOTA-R24 Redundant IO Termination Assembly Configured for redundant field I/O termination and 24 VDC power distribution in Honeywell Safety... Baca selengkapnya

SKU: FC-IOTA-R24
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell FC-IOTA-R24 Redundant IO Termination Assembly

    Configured for redundant field I/O termination and 24 VDC power distribution in Honeywell Safety Manager systems, the Honeywell FC-IOTA-R24 (FC-IOTA-R24 Redundant IO Termination Assembly) provides direct physical and electrical execution for connected I/O circuits.

    Hardware Specifications

    Parameter Specification
    Model FC-IOTA-R24
    Brand Honeywell
    Origin USA
    Product Type Redundant IO Termination Assembly
    Weight 0.57 kg (1.26 lbs)
    Dimensions 64 x 120.7 x 443.2 mm (2.52 x 4.75 x 17.45 in)
    Operating Temp -40 to +70 deg C (-40 to +158 deg F)
    Storage Temp -40 to +85 deg C (-40 to +185 deg F)
    Relative Humidity 10 to 95% non-condensing
    Pollution Degree Pollution degree 2 or better
    Power Consumption Supply load: max. 10 A
    Supply Voltage 24 VDC -15% to +30%
    Approvals CE, UL, TUV
    Reverse Polarity Protection Parallel diode protection (blows fuse)
    Fuse Rating 15 A
    Fuse Type Blade fuse, 5 x 19 mm
    Fuse Voltage Rating 32 VDC
    Fuse Manufacturer Littelfuse
    Fuse Part Number 0287015.PXS
    V+ Terminal Current Max. 1 A total across four CN3 pins
    V+ Voltage Drop Less than 1.5 V at 0.7 A
    V+ Reverse Voltage Max. 36 V
    24 V Supply Connection 2 x M4 connections to carrier power rail
    Ground Connection 10 x M3.5 connections to carrier metal structure
    Ethernet Interface RJ-45
    IO Connectors CN1 and CN2: Weidmuller BLZ 5.08/16/90F SN SW
    V+ Connector CN3: Weidmuller BLZ 5.08/4/90F SN SW
    Screw Terminal Wire Size 0.50 to 2.50 mm2
    Screw Terminal Strip Length 7 mm
    Screw Terminal Tightening Torque 0.5 Nm (0.37 ft-lb)

    Honeywell Process Control Signal Termination Features

    The FC-IOTA-R24 provides redundant I/O field termination functions with dedicated terminal interfaces for signal wiring, power distribution, and carrier connections. Moreover, the assembly manages 24 VDC supply routing through protected terminals and integrates reverse polarity protection using a parallel diode circuit with fuse interruption.

    The unit supports structured wiring within Honeywell safety control architectures by separating field connections from carrier-level power interfaces. In addition, the termination assembly maintains electrical isolation requirements between connected field devices and system-level interfaces through controlled terminal arrangements.

    The FC-IOTA-R24 supports industrial process control installations where DCS and safety system I/O circuits require organized termination. Furthermore, Honeywell process platforms commonly implement channel-to-channel isolation concepts and signal integrity control for analog and digital field interfaces, although this assembly specifically provides termination and distribution functions rather than measurement processing.

    Frequently Asked Questions

    Q: Does the FC-IOTA-R24 provide active I/O signal processing functions?
    A: No. The FC-IOTA-R24 functions as a redundant I/O termination assembly and provides field connection, power distribution, and wiring management functions.

    Q: What protection method does the FC-IOTA-R24 use against incorrect supply polarity?
    A: The assembly uses a parallel diode reverse polarity protection circuit. When reverse voltage occurs, the protection path causes the fuse to disconnect the supply circuit.

    Q: What type of field wiring connection does the FC-IOTA-R24 support?
    A: The assembly uses Weidmuller screw terminal connectors for CN1, CN2, and CN3 interfaces. The terminals accept 0.50 to 2.50 mm2 wire sizes with a 7 mm strip length.

    Field Installation Guidelines

    • Install the FC-IOTA-R24 on the specified carrier assembly and secure all mechanical mounting points before wiring.
    • Connect the 24 VDC supply through the dedicated M4 power rail connections and verify polarity before energizing the system.
    • Connect the grounding terminals to the carrier metal structure to maintain the required protective bonding path.
    • Route Ethernet and I/O wiring separately from high-voltage power cables to reduce electrical interference.
    • Verify CN1, CN2, and CN3 terminal assignments before field connection to prevent incorrect signal routing.
    • Tighten screw terminals according to the specified torque requirement and confirm cable retention after installation.
    • Inspect fuse status and supply polarity protection before commissioning the redundant I/O termination assembly.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama