Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

CC-IP0101 | Honeywell | Series 8 PROFIBUS Gateway Module

CC-IP0101 | Honeywell | Series 8 PROFIBUS Gateway Module

Formulir produk

Honeywell CC-IP0101 Series 8 PROFIBUS Gateway Module Configured for bridging Honeywell Experion LX or Experion PKS systems with PROFIBUS DP... Baca selengkapnya

SKU: CC-IP0101 51410056-175
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Honeywell CC-IP0101 Series 8 PROFIBUS Gateway Module

    Configured for bridging Honeywell Experion LX or Experion PKS systems with PROFIBUS DP fieldbus networks, the Honeywell CC-IP0101 (51410056-175 PROFIBUS Gateway Module) provides direct physical/electrical execution. Operating in the Series 8 form factor, this hardware component acts as a dedicated PROFIBUS DP master interface to handle deterministic data exchange between a C300 controller and up to 125 field nodes per segment. It manages physical signal processing and protocol execution directly within the Honeywell distributed control architecture.

    Hardware Specifications

    Parameter Specification
    Model CC-IP0101
    Part Number / Spare Model 51410056-175
    Brand Honeywell
    Module Type PROFIBUS DP Gateway Module (DP-2)
    Origin USA
    Weight 0.4 kg
    Estimated Shipping Size 5.5 x 15.5 x 14.5 cm
    Voltage Input 24 VDC (+/-10%)
    Current Consumption 150 mA (idle), 500 mA (full load), 390 mA nominal
    Max Nodes 125 nodes per segment (up to 127 field devices total)
    Isolation Voltage 500 VAC
    Connector Interface 9-pin D-sub or terminal block
    Operating Temperature -20 to +60 deg C (-4 to +140 deg F)
    Storage Temperature -40 to +85 deg C (-40 to +185 deg F)
    Humidity 5-95% RH (non-condensing)
    Tariff Code 8537101190

    Process Control & Distributed System Integration

    The module implements native channel-to-channel isolation and hardware interfaces optimizing connection to process control instruments. It handles deterministic mapping of fieldbus variables into the Experion control database, ensuring synchronization for 4-20 mA HART loop protocols and downstream PROFIBUS PA connectivity via standard linking devices. Cold junction compensation (CJC) and analog signal scaling calculations are managed at the controller level, while this module maintains hardware-level communication timing, sequence-of-events capturing, and bulk build utility processing across the local network interface.

    Frequently Asked Questions

    Q: How is the redundancy behavior executed between primary and secondary modules?

    A: Redundancy is managed via hardware pairing over the Series 8 backplane. Upon failure of the primary gateway, the backup module executes a cold start command and assumes the active PROFIBUS DP master role, inheriting the network topology configurations and node states without requiring manual reconfiguration from the master C300 controller.

    Q: What is the maximum node capacity and electrical limitation per physical network segment?

    A: The module supports up to 125 nodes per segment. The physical layer relies on standard RS-485 transceiver limits; if more than 31 field nodes are connected to a single electrical segment without segmentation, PROFIBUS DP repeaters must be installed to maintain signal integrity and respect the 500 VAC isolation rating.

    Field Installation Guidelines

    • Mounting Orientation: Secure the Series 8 module onto the designated Input Output Termination Assembly (IOTA) block. Ensure all locking mechanisms are fully engaged before applying 24 VDC power.
    • Wiring and Shielding: Terminate the PROFIBUS DP network cable using a standard shielded 9-pin D-sub connector or the provided terminal block. The cable shield must be grounded at both ends of the segment using low-impedance grounding clamps to mitigate high-frequency electromagnetic interference.
    • Bus Termination: Active termination resistors must be enabled and powered at both physical ends of the PROFIBUS DP segment. Do not enable termination on the CC-IP0101 module unless it sits at the absolute physical end of the cable run.
    • Environmental Constraints: Maintain clearance around the module housing to allow passive convection cooling, ensuring ambient temperatures inside the enclosure do not exceed +60 deg C.

    Spesifikasi

    • Merek: Honeywell

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun