Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

BMXDDI6402K Schneider Electric Modicon X80 Discrete Input Module

BMXDDI6402K Schneider Electric Modicon X80 Discrete Input Module

Formulir produk

Schneider Electric BMXDDI6402K Discrete Input Module Configured for acquisition of 24 VDC discrete field signals in Modicon X80 backplane systems,... Baca selengkapnya

SKU: BMXDDI6402K
Negara asal: France

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Schneider Electric BMXDDI6402K Discrete Input Module

    Configured for acquisition of 24 VDC discrete field signals in Modicon X80 backplane systems, the Schneider Electric BMXDDI6402K (BMXDDI6402K Discrete Input Module) provides direct physical/electrical execution for 64-channel digital input scanning across X80 distributed I/O architectures.

    The module operates as a 64-channel isolated input interface with positive logic current sink configuration, designed for 24 V DC sensor environments. Signal detection thresholds support standard industrial switching levels with diagnostic feedback per channel. Internal processing is synchronized via the X80 backplane with defined response time behavior for deterministic input acquisition.

    Suffix Breakdown & Model Matrix

    No explicit suffix segmentation or variant encoding is defined in the provided manufacturer dataset for BMXDDI6402K. The identifier is treated as a single fixed-order catalog number.

    Hardware Specifications

    Parameter Specification
    ModelBrand Schneider Electric BMXDDI6402K
    Weight 0.145 kg
    OperatingTemp 0 degC to 60 degC
    PowerConsumption 4.3 W
    Input Channels 64 discrete inputs
    Input Type Isolated, current sink (positive logic)
    Input Voltage 24 V DC positive
    Input Current 0.6 mA
    Backplane Consumption 160 mA at 3.3 V DC
    Response Time 4 ms typical, 7 ms max
    Sensor Supply Range 19 V to 30 V DC
    Insulation Resistance > 10 MOhm at 500 V DC

    Schneider Electric X80 Backplane Input Architecture

    The module integrates into Modicon X80 rack systems using a high-speed backplane communication structure supporting synchronized I/O refresh cycles. Each channel is electrically isolated to reduce cross-channel interference under dense wiring conditions. Input filtering is implemented to stabilize signal acquisition under industrial noise conditions typical of distributed cabinet wiring. Channel diagnostics are individually indicated via per-point LEDs, enabling direct field-level fault localization without external test instrumentation. Backplane power draw at 3.3 V DC remains within low-load I/O module class consumption envelope (160 mA typical), supporting multi-module rack density planning.

    Frequently Asked Questions

    Q: Can the module be hot-swapped under energized rack conditions?
    A: The BMXDDI6402K supports Modicon X80 rack insertion/removal behavior when system configuration permits, however field power sequencing must follow backplane and rack manufacturer constraints to avoid transient I/O state instability.

    Q: Does channel isolation prevent cross-talk between adjacent inputs?
    A: Each input channel is isolated with internal impedance of approximately 40 kOhm and designed to limit electrical coupling between channels under 24 V DC switching conditions.

    Q: What is the impact of backplane load on multi-module configurations?
    A: Each module contributes approximately 160 mA at 3.3 V DC to the backplane load budget; total rack consumption must be aggregated across all installed X80 modules.


    Field Installation Guidelines

    DIN rail rack insertion shall be performed with backplane power removed unless system architecture explicitly supports live insertion procedures. Field wiring must maintain segregation between input signal bundles and power conductors to minimize inductive coupling. Shield termination should be implemented at cabinet ground reference points only, avoiding dual-ended grounding loops on 24 V DC discrete circuits. Channel grouping should respect fuse-protected input groups (0.5 A fast-blow external protection per group). Ambient installation must remain within 0 to 60 degC operating envelope with humidity control below condensation threshold conditions.

    Spesifikasi

    • Merek: Schneider Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun