Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

BMXCRA31210 Safety Ethernet RIO Drop Adaptor | Schneider Electric

BMXCRA31210 Safety Ethernet RIO Drop Adaptor | Schneider Electric

Formulir produk

Schneider Electric BMXCRA31210 Modicon X80 Ethernet RIO Drop Adaptor Configured for deterministic remote I/O communication in the Modicon X80 distributed... Baca selengkapnya

SKU: BMXCRA31210
Negara asal: France

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Schneider Electric BMXCRA31210 Modicon X80 Ethernet RIO Drop Adaptor

    Configured for deterministic remote I/O communication in the Modicon X80 distributed I/O architecture, the Schneider Electric BMXCRA31210 (base model BMXCRA) provides direct physical backplane bus bridging and EtherNet/IP protocol execution. This adapter manages cyclic input data acquisition and output updates between the remote head adaptor and local I/O modules via the X bus backplane.

    Hardware Specifications

    Parameter Specification
    Brand Schneider Electric
    Origin France
    Weight 270 g
    Dimensions 125 x 110 x 55 mm
    Operating Temp 0 to 60 degC
    Power Consumption 1.5 W typical (via backplane)
    Bus Type X Bus (Remote Backplane)
    Ports 3 x RJ45
    Supported Channels 0 to 1024 discrete / 0 to 256 analog
    Protocols EtherNet/IP, RSTP

    EtherNet/IP Deterministic Networks and Firmware Flash Compatibility

    The BMXCRA31210 executes real-time data exchange using scheduled I/O messaging over EtherNet/IP. It supports Configuration Change on the Fly (CCOTF), allowing modification of I/O parameters without processor stoppage, contingent upon firmware flash compatibility with the local rack controller. The module maintains data integrity through 10 ms timestamp recording for diagnostic logging. Network topology supports daisy chain loops utilizing Rapid Spanning Tree Protocol (RSTP) to ensure deterministic recovery times.

    Frequently Asked Questions

    Q: Does the BMXCRA31210 support hot-swap insertion?

    A: No. The module must be inserted into a powered-down backplane. Hot-swapping may cause backplane bus contention and data corruption.

    Q: What is the maximum backplane current load imposed by this adaptor?

    A: The module draws approximately 300 mA at 3.3 VDC from the backplane power supply. Ensure the rack power budget accounts for this load.

    Q: Is explicit messaging supported through the service port?

    A: The service port is restricted to configuration and diagnostics. It does not support cyclic I/O data exchange required for control logic execution.

    Field Installation Guidelines

    Mount the module in a standard Modicon X80 rack slot. Torque terminal connections to 0.5 N·m. Maintain a minimum bend radius of 50 mm for Ethernet cables to prevent pair untwisting. Ground the shield drain wire to the rack ground bus bar at one end only to mitigate common-mode noise. Verify IP addressing and subnet masks prior to establishing the EtherNet/IP connection to avoid broadcast storms.

    Spesifikasi

    • Merek: Schneider Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun