    Keterangan

    Schneider Electric BMXART0814 Modicon X80 Analog Input Module

    The Schneider Electric BMXART0814, also cataloged as the BMXART0814 Analog Input Module, operates as a dedicated hardware component for low-level temperature signal acquisition within the Modicon X80 automation platform. The module provides eight isolated analog input channels supporting thermocouple and temperature probe measurement with sigma-delta conversion and integrated diagnostic indication.

    Hardware Specifications

    Parameter Specification
    Model BMXART0814
    Brand Schneider Electric
    Series Modicon X80
    Product Type Analog Input Module
    Analog Inputs 8 isolated channels
    Input Level Low level
    Electrical Connection Two 40-pin connectors
    Analog/Digital Conversion Sigma-delta, 16-bit
    Analog Resolution 15 bits + sign
    Supported Measurements Thermocouple, temperature probe
    Cold Junction Compensation External Pt100 probe
    Digital Filter First-order digital filtering
    Nominal Read Cycle 200 ms (thermocouple); 400 ms (temperature probe)
    Permitted Input Overload +/- 7.5 V with specified measurement ranges
    Common Mode Rejection 120 dB at 50/60 Hz
    Differential Mode Rejection 60 dB at 50/60 Hz
    Status Indicators RUN, channel diagnostic, ERR, I/O LEDs
    Isolation Channel-to-channel isolated
    Operating Altitude 0 to 2000 m; up to 5000 m with derating
    Operating Temp 0 to 60 degC
    Storage Temp -40 to 85 degC
    Relative Humidity 5% to 95% at 55 degC, non-condensing
    IP Rating IP20
    Vibration Resistance 3 gn
    Shock Resistance 30 gn
    Certifications CE, UL, CSA, EAC, RCM, Merchant Navy
    Standards EN 61131-2, EN 61000-6-2, EN 61000-6-4, EN 61010-2-201
    Environmental Classification IEC 60721-3-3 Class 3C3, 3C4
    Weight 0.165 kg
    Dimensions Not specified
    Power Consumption Not specified
    Origin Not specified

    PLC Backplane Communication and I/O Density

    The BMXART0814 exchanges measurement data through the Modicon X80 backplane architecture. Eight isolated input channels allow temperature acquisition without increasing signal interaction between adjacent channels. Sigma-delta conversion and first-order digital filtering are implemented to process low-level analog inputs before transmission to the controller over the backplane bus.

    Frequently Asked Questions

    Q: Does the module provide channel isolation?

    A: Yes. Each of the eight analog input channels is electrically isolated, reducing interference between measurement circuits.

    Q: Is cold junction compensation integrated into the module?

    A: The module performs cold junction compensation using an external Pt100 probe connected according to the application requirements.

    Q: Can the module measure both thermocouples and temperature probes?

    A: Yes. The specified nominal conversion cycle is 200 ms for thermocouple measurement and 400 ms for temperature probe measurement.

    Field Installation Guidelines

    • Install the module only in a compatible Modicon X80 rack with power removed before insertion or removal unless the system documentation explicitly permits online replacement.
    • Route thermocouple and low-level analog wiring separately from power and motor cables to minimize induced electrical noise.
    • Connect cable shields according to the plant grounding practice and avoid multiple shield grounding points unless specified by the control system design.
    • Install the external Pt100 sensor for cold junction compensation as specified by the wiring documentation.
    • Maintain adequate enclosure ventilation so the ambient operating temperature remains within the specified 0 to 60 degC range.

    Spesifikasi

    • Merek: Schneider Electric

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun