Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Bently Nevada 3300/16-12-01-01-00-00 Dual Vibration Monitor Module

Bently Nevada 3300/16-12-01-01-00-00 Dual Vibration Monitor Module

Formulir produk

Bently Nevada 3300/16-12-01-01-00-00 Dual Vibration Monitor Module Configured for radial vibration and gap signal conditioning in 3300 Machinery Monitoring System,the Bently... Baca selengkapnya

SKU: 3300/16-12-01-01-00-00
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 3300/16-12-01-01-00-00 Dual Vibration Monitor Module

    Configured for radial vibration and gap signal conditioning in 3300 Machinery Monitoring System,the Bently Nevada 3300/16-12-01-01-00-00 (3300/16 Dual Vibration Monitor Module) provides direct physical/electrical execution. The module processes dual proximity probe inputs for vibration amplitude and average shaft position (gap), converting eddy-current transducer signals into conditioned analog outputs and relay trip logic.

    Suffix Breakdown & Model Matrix

    Code Segment Function Configuration
    3300/16 Base Module XY / Gap Dual Vibration Monitor
    -12 Full Scale Range 0 to 150 um pp
    -01 Input Type 3300 / 7200 / 3300XL Proximitor compatible
    -01 Relay Type Epoxy sealed SPDT relays
    -00 Agency Approval None
    -00 Safety Barriers Not installed
    -00 Trip Multiply Not enabled

    HardwareSpecifications

    Parameter Specification
    ModelBrand Bently Nevada 3300/16-12-01-01-00-00
    OperatingTemp 0 degC to +65 degC
    PowerConsumption 2 W nominal
    Input Channels 1 or 2 proximity probe inputs
    Input Impedance 10 kOhm
    Frequency Response 4 Hz to 4000 Hz (standard), 1 Hz to 600 Hz (low speed option)
    Recorder Outputs 4 to 20 mA, 0 to -10 VDC, 1 to 5 VDC selectable
    Relay Output SPDT epoxy sealed
    Buffered Output Front panel coaxial per channel

    Eddy Current Probe Scaling and Gap Voltage Validation

    The module interfaces with eddy-current proximity transducers using calibrated scaling typically based on 200 mV/mil sensitivity (approx 7.87 V/mm). Input conditioning circuitry performs continuous gap voltage validation against expected shaft position windows, ensuring stable DC offset tracking across thermal drift conditions.

    Cross-talk suppression is implemented at the channel separation stage, where dual-channel processing isolates orthogonal vibration vectors (X and Y axes). This prevents phase coupling errors in rotor dynamic interpretation, particularly in closely mounted probe geometries.

    Rotor dynamic response is derived from band-limited vibration extraction, with selectable frequency windows optimized for low-speed shaft behavior below 1000 RPM and high-speed turbomachinery profiles up to 4000 Hz.

    Frequently Asked Questions

    Q: Can the module operate with a single proximity probe input only?
    A: Yes. The second channel can remain unused, but channel diagnostics will flag inactive input unless bypassed via configuration.

    Q: Does hot-swapping the module affect backplane signal integrity?
    A: The 3300 rack architecture does not support live hot-swap without transient interruption on shared backplane lines.

    Q: What determines relay trip activation timing?
    A: Relay actuation is governed by internal comparison logic between filtered vibration signal and configured alert/danger thresholds with fixed processing latency.


    Field Installation Guidelines

    Install the module only in a compatible 3300 rack slot with verified backplane alignment. Maintain shield continuity for all proximity probe cabling and ensure single-point grounding at the system chassis.

    Avoid routing low-level probe signals alongside high-energy switching conductors to minimize induced noise. Torque all terminal connections to manufacturer-recommended mechanical retention limits.

    Verify channel scaling calibration prior to commissioning using known gap reference voltages. Ensure airflow clearance within enclosure remains unobstructed for thermal stability under continuous 2 W dissipation.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun