Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Bently Nevada 200200-03-03-05 Temperature Interface Modules

Bently Nevada 200200-03-03-05 Temperature Interface Modules

Formulir produk

Bently Nevada 200200-03-03-05 Trendmaster proTIM-R Temperature Interface Module The Bently Nevada 200200-03-03-05, also cataloged as the 200200 proTIM-R Temperature Interface... Baca selengkapnya

SKU: 200200-03-03-05
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 200200-03-03-05 Trendmaster proTIM-R Temperature Interface Module

    The Bently Nevada 200200-03-03-05, also cataloged as the 200200 proTIM-R Temperature Interface Module, operates as a dedicated hardware component for dual-channel RTD temperature signal acquisition within the Trendmaster distributed condition monitoring system.

    Hardware Specifications

    Parameter Specification
    Model 200200-03-03-05
    Brand Bently Nevada
    Product Series Trendmaster 200 Series proTIM-R
    Module Type Processor Transducer Interface Module
    Origin United States
    Weight Approx. 0.77 lbs (349 grams)
    Dimensions Approx. 11.6 cm x 2.5 cm x 2.0 cm
    Input Channels 2 independent temperature input channels
    Sensor Input Type 2-wire or 3-wire Platinum RTD (Pt100 typical)
    Mounting Method 35 mm DIN rail mounting
    Signal Processing Analog signal conditioning and digital conversion
    Electrical Isolation Isolated temperature input channels
    System Interface Trendmaster data highway communication

    Rotor Temperature Signal Processing and Mechanical Monitoring Features

    The Bently Nevada 200200-03-03-05 processes RTD temperature signals through dedicated input conditioning circuits before transferring measurement data to the Trendmaster monitoring network. Moreover, the isolated channel design reduces ground loop influence during temperature measurement in distributed machinery monitoring installations.

    This proTIM-R module supports thermal condition measurement for rotating equipment components through Platinum RTD inputs. In addition, the module architecture follows Bently Nevada monitoring practices that maintain measurement integrity for machinery diagnostics, including sensor signal scaling and verification methods used in condition monitoring systems.

    The module operates within the Trendmaster platform where temperature data contributes to machinery protection analysis. Furthermore, the hardware design supports separation between field sensor wiring and system communication paths to reduce signal interference.

    Frequently Asked Questions

    Q: What type of sensors can the Bently Nevada 200200-03-03-05 accept?
    A: The module accepts 2-wire or 3-wire Platinum RTD temperature sensors, typically configured with Pt100 resistance elements.

    Q: Does the 200200-03-03-05 provide isolated temperature inputs?
    A: Yes. The module provides isolated temperature input channels to reduce electrical interference and ground loop effects between field devices.

    Q: Can this module be installed on a standard industrial DIN rail?
    A: Yes. The module uses a 35 mm DIN rail mounting configuration for installation inside industrial control cabinets.

    Field Installation Guidelines

    Install the 200200-03-03-05 module on a properly secured 35 mm DIN rail inside an enclosure that meets the environmental requirements of the installation location.

    Connect RTD sensor wiring according to the selected 2-wire or 3-wire configuration. Use shielded instrumentation cable where required, and terminate cable shields according to the plant grounding standard to minimize electrical noise.

    Separate RTD signal cables from high-voltage power conductors, motor cables, and switching circuits. Additionally, verify terminal connections before system startup to prevent incorrect temperature readings caused by wiring errors.

    Confirm communication wiring between the proTIM-R module and the Trendmaster network before commissioning. Therefore, perform signal verification using the system configuration software to validate channel assignment and temperature measurement response.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun