Bently Nevada 18745-02 7200 Series Monitor Module The Bently Nevada 18745-02, also cataloged as the 18745 dual-channel monitor module, operates...
Baca selengkapnya
Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .
Hubungi kami: +86 135 995 07613
Tersedia pada hari kerja antara pukul 09.00 hingga 18.00
Email kami: sales2@industriaxplc.com
Tersedia 24/7 untuk pertanyaan dan dukungan
Keterangan
Bently Nevada 18745-02 7200 Series Monitor Module
The Bently Nevada 18745-02, also cataloged as the 18745 dual-channel monitor module, operates as a dedicated hardware component for continuous radial vibration and thrust position measurement within the 7200 Series Proximity Transducer System.
Hardware Specifications
Parameter
Specification
Model
18745-02
Brand
Bently Nevada (Baker Hughes)
Origin
USA
Weight
Approx. 0.35 kg
Dimensions
Standard 7200 series card form factor
Operating Temp
0 deg C to +65 deg C
Storage Temp
-40 deg C to +85 deg C
Humidity
95 % non-condensing
Power Consumption
< 5 W per module
Input Signal
Eddy-current proximity probes (5 mm or 8 mm typical)
Signal Output
4-20 mA or 1-5 Vdc proportional
Buffered Output
Front panel coaxial / rear terminal dynamic output
Relay Outputs
Dry contacts for Alert / Danger, configurable latch mode
Eddy-Current Probe Scaling and Gap Voltage Validation
The 18745-02 applies linearized scaling factors between probe tip displacement and output voltage, maintaining proportional accuracy across the specified target gap range. Gap voltage validation logic continuously samples the DC bias level against a nominal -10 VDC reference, ensuring correct probe standoff before enabling trip signaling. This prevents false machinery shutdown due to probe contact loss or target surface anomalies.
Frequently Asked Questions
Q: Does the module support hot-swap replacement in the 7200 rack?
A: No. The 7200 system backplane does not support live insertion; power must be removed before removing or installing the 18745-02 to avoid transient faults.
Q: Can both channels operate with different probe types?
A: Both channels must use compatible eddy-current transducer types within the same module. Mixing 5 mm and 8 mm probes requires separate configuration verification for each channel's scale factor.
Q: What is the relay switching delay in danger condition?
A: Relay activation occurs within milliseconds after exceeding the configured danger setpoint, subject to any user-set time delay jumper configuration.
Field Installation Guidelines
Install the 18745-02 into the designated 7200 rack slot, ensuring correct alignment with guide rails and backplane connectors. Apply even pressure during insertion to avoid connector pin damage. Use shielded twisted-pair cable for probe signal wiring, grounding the shield at the rack end only to minimize ground loops. Verify gap voltage at each probe prior to enabling monitoring functions. Perform functional testing by simulating probe displacement and confirming proportional output change and alarm relay operation.