Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Bently Nevada 141380-01 FieldMonitor Isolated Input Terminal Base

Bently Nevada 141380-01 FieldMonitor Isolated Input Terminal Base

Formulir produk

Bently Nevada 141380-01 FieldMonitor Isolated Input Terminal Base The Bently Nevada 141380-01, also cataloged as the 141380-01 FieldMonitor Isolated Input Terminal Base (ITB),... Baca selengkapnya

SKU: 141380-01
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 141380-01 FieldMonitor Isolated Input Terminal Base

    The Bently Nevada 141380-01, also cataloged as the 141380-01 FieldMonitor Isolated Input Terminal Base (ITB), operates as a dedicated hardware component for electrical isolation and sensor termination within FieldMonitor 1701 series vibration monitoring architectures. The module implements channel-separated input routing for vibration transducers, maintaining galvanic separation between field wiring and downstream monitoring electronics. It provides direct physical termination and isolation for multi-channel sensor acquisition without active signal conditioning circuitry.

    Hardware Specifications

    Parameter Specification
    Model 141380-01
    Brand Bently Nevada
    Weight 1.6 kg
    Dimensions 127 x 203 x 508 mm
    Operating Temp -40 deg C to +70 deg C
    Power Consumption Passive (no active draw)
    Isolation Voltage 250 VAC continuous, 1500 VAC test
    Channels 6 isolated input channels
    Connections Screw terminals, 12–22 AWG
    Mounting DIN rail
    Storage Temperature -40 deg C to +85 deg C
    Humidity 5%–95% RH non-condensing
    Housing Material Thermoplastic

    Bently Nevada Mechanical Monitoring Interface Behavior

    The 141380-01 ITB is positioned within Bently Nevada FieldMonitor systems to support signal segregation for vibration and proximity transducers. In typical TSI signal chains, eddy-current probe scaling is preserved by maintaining low leakage paths across isolated channels, ensuring stable gap voltage reference integrity (commonly validated around negative DC bias regions such as -10 VDC measurement envelopes in compatible proximitor architectures).

    Within rotor dynamics monitoring loops, channel-to-channel isolation reduces cross-talk propagation between adjacent sensor lines during high vibration amplitude conditions. This preserves phase-referenced waveform fidelity used in shaft orbit analysis and synchronous extraction. The terminal base does not perform signal conditioning; therefore, waveform integrity is fully dependent on upstream probe calibration and correct termination practices.

    Suffix Breakdown & Model Matrix

    No structured suffix segmentation is defined for model 141380-01. The designation is treated as a fixed-order identifier within the FieldMonitor ITB hardware family.

    Frequently Asked Questions (FAQ)

    Q: Does the 141380-01 support hot-swap replacement under energized FieldMonitor systems?
    A: The ITB is a passive termination base; replacement under energized conditions is dependent on system-level FieldMonitor 1701 series configuration and wiring isolation procedures rather than internal electronics behavior.

    Q: What is the impact of channel isolation on back-to-back vibration signal acquisition?
    A: Each of the 6 channels is galvanically isolated, reducing inter-channel leakage paths and minimizing measurement interference during simultaneous multi-probe vibration sampling.

    Q: Is any backplane current required for operation?
    A: No. The module operates passively and does not draw backplane or external supply current.


    Field Installation Guidelines

    DIN rail mounting must ensure continuous mechanical fixation across the full 508 mm housing length to prevent micro-movement under vibration environments. Signal wiring should follow separated routing paths for low-level transducer signals, avoiding parallel alignment with high-voltage conductors.

    Screw terminal connections should be torqued according to standard industrial control cabinet practices for 12–22 AWG conductors, ensuring stable contact resistance. Shielded cable drains should be terminated at a single-point ground reference to avoid ground loop formation across isolated channels.

    Isolation integrity should be verified after installation using dielectric test procedures consistent with the specified 1500 VAC test rating.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun