Formulir produk

Bently Nevada 141378-01 FieldMonitor Power Supply Module Configured for regulated 24 VDC power distribution in FieldMonitor vibration monitoring systems, the Bently... Baca selengkapnya

SKU: 141378-01
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 141378-01 FieldMonitor Power Supply Module

    Configured for regulated 24 VDC power distribution in FieldMonitor vibration monitoring systems, the Bently Nevada 141378-01 (141378-01 FieldMonitor Power Supply Module) provides direct physical/electrical execution of AC/DC conversion and stabilized DC rail generation within 1701/05 and 1701/06 terminal base architectures.

    Suffix Breakdown & Model Matrix

    No validated functional suffix segmentation is defined for this order number.

    • 141378-01: FieldMonitor power supply module identifier within 1700-series system structure

    • No additional configuration decoding provided in the source dataset

    Hardware Specifications

    Parameter Specification
    Model 141378-01
    Brand Bently Nevada
    Weight 0.4 kg
    Dimensions 45 x 100 x 117 mm
    Operating Temp -10 deg C to +60 deg C
    Power Consumption Input dependent (AC/DC conversion module)
    Input Voltage 100–240 VAC or 18–36 VDC
    Output Voltage 24 VDC
    Output Current Up to 2.5 A
    Efficiency ~88%
    Ripple & Noise <100 mVpp
    Mounting DIN rail
    Storage Temperature -40 deg C to +85 deg C
    Humidity 5–95% RH non-condensing
    Protections Overvoltage, thermal overload, short-circuit
    Indicators LED power status

    Power Rail Regulation and Voltage Conditioning Behavior in FieldMonitor Systems

    The module operates as a regulated DC power conversion stage within FieldMonitor system backplane architecture. It converts wide-range AC or DC inputs into a stabilized 24 VDC distribution rail used by vibration monitoring and terminal base modules.

    Within multi-module rack configurations, output ripple suppression (<100 mVpp) maintains stable supply conditions for downstream signal conditioning electronics. This reduces susceptibility to voltage modulation effects on transducer excitation circuits and analog front-end stages.

    From a system-level perspective, the module includes internal protection coordination logic for overvoltage and thermal shutdown conditions. These mechanisms isolate fault propagation from the 24 VDC rail, limiting disturbance coupling into adjacent FieldMonitor modules during transient load events.

    Frequently Asked Questions (FAQ)

    Q: Can the 141378-01 be hot-swapped during operation?
    A: It is not intended for live insertion or removal under load. Input power isolation is required to avoid transient voltage spikes on the 24 VDC rail.

    Q: What happens if input polarity is reversed on the DC supply input?
    A: Reverse polarity can trigger internal protection or cause functional failure of the conversion stage depending on severity and duration.

    Q: Does output current derate at elevated ambient temperature?
    A: Thermal protection circuitry may reduce output capability or trigger shutdown when internal temperature exceeds defined limits.


    Field Installation Guidelines

    • Install on grounded DIN rail with mechanical locking engaged across full module length

    • Verify correct AC or DC input polarity before energizing the module

    • Maintain separation between input power wiring and low-level sensor signal cabling

    • Ensure enclosure ventilation to prevent thermal accumulation under continuous 2.5 A load

    • Check LED status indicator after power-up to confirm stable 24 VDC output rail formation

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama