Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Bently Nevada 136751-02 3500 Series Isolated I/O Module

Bently Nevada 136751-02 3500 Series Isolated I/O Module

Formulir produk

Bently Nevada 136751-02 3500 Series Isolated I/O Module The Bently Nevada 136751-02, also cataloged as the 136751-02 Isolated I/O Module,... Baca selengkapnya

SKU: 136751-02
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 136751-02 3500 Series Isolated I/O Module

    The Bently Nevada 136751-02, also cataloged as the 136751-02 Isolated I/O Module, operates as a dedicated hardware component for signal isolation and sensor interface processing within the Bently Nevada 3500 Machinery Protection System.

    Hardware Specifications

    Parameter Specification
    Model 136751-02
    Brand Bently Nevada (Baker Hughes)
    Origin USA
    Weight Approx. 1.0 kg
    Dimensions Approx. 190 mm x 128 mm x 20 mm
    Operating Temp -20 deg C to +60 deg C
    Power Consumption Rack supplied power; value not specified
    Product Type Isolated I/O Module with Internal Barriers
    Function Galvanic signal isolation and field sensor interfacing
    System Platform Bently Nevada 3500 Machinery Protection System
    Isolation Method Electrical isolation between field wiring and monitoring rack circuits
    Application Signals Proximity probe, vibration, thrust position, and displacement monitoring signals

    Eddy-Current Probe Signal Isolation and TSI Interface

    The 136751-02 module is designed for use with machinery monitoring signal paths where proximity probe inputs require separation from rack-level monitoring electronics. The internal barrier architecture reduces the effects of ground loops, electrical interference, and transient disturbances on eddy-current probe measurement circuits.

    Within TSI (Turbine Supervisory Instrumentation) applications, signal integrity depends on correct probe scaling, gap voltage validation, and stable transmission of dynamic shaft displacement data. Bently Nevada monitoring systems commonly use -10 VDC probe gap voltage targets as a reference condition for eddy-current probe installation verification. The isolated I/O module supports signal conditioning paths used for rotor dynamics analysis, including radial vibration, axial position, and mechanical displacement measurements.

    Frequently Asked Questions

    Q: Does the 136751-02 provide direct sensor excitation for all connected field devices?
    A: The module functions as an isolated interface component. Sensor excitation capability depends on the connected Bently Nevada monitoring module and system configuration.

    Q: Can the 136751-02 eliminate all electrical interference in a machinery monitoring circuit?
    A: The module provides galvanic isolation to reduce ground loop effects and electrical noise coupling. Proper shielding, grounding, and field wiring practices remain required.

    Q: Is the 136751-02 compatible with non-Bently Nevada monitoring racks?
    A: The module is designed for integration within the Bently Nevada 3500 system architecture. Compatibility with other platforms requires verification of mechanical, electrical, and communication interfaces.

    Field Installation Guidelines

    • Install the module in the designated Bently Nevada 3500 rack position according to system configuration requirements.
    • Verify field wiring polarity and terminal assignments before applying power.
    • Maintain separation between low-level sensor signal wiring and high-voltage or high-current conductors.
    • Connect cable shields according to the machinery monitoring system grounding design to reduce noise coupling.
    • Confirm proximity probe wiring integrity and verify probe gap voltage before commissioning.
    • Inspect module seating, rack connectors, and retention hardware during installation.
    • Follow the applicable Bently Nevada 3500 system manual for rack configuration and commissioning procedures.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama