Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Bently Nevada 134M2166-01 / 134M6794-01 Proximitor Monitor Module

Bently Nevada 134M2166-01 / 134M6794-01 Proximitor Monitor Module

Formulir produk

Bently Nevada 134M2166-01 / 134M6794-01 Proximitor Monitor Module Configured for proximity probe signal conditioning in Bently Nevada Proximitor measurement chains,... Baca selengkapnya

SKU: 134M2166-01 134M6794-01
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Bently Nevada 134M2166-01 / 134M6794-01 Proximitor Monitor Module

    Configured for proximity probe signal conditioning in Bently Nevada Proximitor measurement chains, the Bently Nevada 134M2166-01 / 134M6794-01 (134M2166-01 / 134M6794-01 Proximitor Monitor Module) provides direct electrical processing of eddy-current probe inputs within a TSI signal acquisition architecture.

    The module processes low-level displacement signals from non-contacting proximity probes and converts them into calibrated shaft dynamic and position outputs. Signal paths are designed for continuous acquisition of radial vibration, axial thrust position, and slow-roll eccentricity behavior during machine start-up and steady-state operation. Output scaling is referenced to probe gap voltage transfer characteristics, typically validated against -10 VDC linear operating regions in eddy-current transducer chains.

    Suffix Breakdown & Model Matrix

    • 134M2166-01: Base monitor/interface assembly identifier used in configured Proximitor channel processing systems
    • 134M6794-01: Associated revision or mating assembly identifier used for system-level compatibility mapping
    • No further structured suffix segmentation is defined in provided technical data; internal revision encoding is manufacturer-specific

    Hardware Specifications

    Parameter Specification
    Model 134M2166-01 / 134M6794-01
    Brand Bently Nevada
    Origin United States
    Weight 1kg
    Dimensions Not specified
    Operating Temp -40 deg C to +85 deg C (system-dependent envelope)
    Power Consumption 24 VDC nominal system supply (current not specified)
    Input Type Eddy-current proximity probe signal
    Signal Processing Radial vibration, axial position, eccentricity
    Output Scaling Probe-dependent (e.g., 100 mV/mil or equivalent metric scaling)
    Output Impedance 50 ohm

    Eddy-Current Probe Scaling and Gap Voltage Validation (Bently Nevada Architecture)

    The module operates within a calibrated eddy-current transducer chain where probe tip geometry, extension cable length, and proximitor driver linearity define the final transfer function. Gap voltage validation is performed against standardized linear regions, typically referenced around negative supply bias conditions (approximately -10 VDC operating midpoint).

    Cross-channel signal isolation is implemented to minimize electrical crosstalk between adjacent vibration measurement axes, ensuring stable rotor dynamic interpretation under high mechanical vibration density environments. Scaling accuracy is dependent on probe family matching and field calibration of the full measurement loop.

    Frequently Asked Questions (FAQ)

    Q: Can the module be hot-swapped during active monitoring operation?
    A: Hot-swap capability is not defined at module level. Removal under energized conditions may interrupt probe bias voltage and invalidate gap reference stability across connected channels.

    Q: What is the typical backplane or system load behavior?
    A: Backplane loading is dependent on chassis configuration. The module draws low-current DC bias typical of proximitor signal conditioning circuits, but exact load distribution depends on rack architecture.

    Q: Is firmware-level synchronization required between paired modules (134M2166-01 and 134M6794-01)?
    A: No firmware synchronization data is specified. Compatibility is determined by hardware revision matching and probe scaling configuration rather than embedded firmware interlock.

    Field Installation Guidelines

    • Maintain coaxial probe cable integrity with continuous shield termination to chassis ground at a single reference point only
    • Avoid sharp bending radius on extension cables to prevent impedance discontinuity in high-frequency eddy-current signal paths
    • Ensure probe gap calibration is performed before system energization to establish baseline DC bias voltage reference
    • Install module within rated enclosure environment to prevent contamination of conformal coated PCB surfaces
    • Verify connector engagement torque consistency for all ClickLoc-style coaxial interfaces to prevent micro-disconnection under vibration load

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun