    Bently Nevada 1034549-40 Dual Galvanic Isolator

    Configured for intrinsic safety signal separation in FieldMonitor systems, the Bently Nevada 1034549-40 (1034549 Dual Galvanic Isolator) provides direct electrical isolation for vibration and position transducer circuits. The module separates field signals and monitoring electronics through galvanic isolation paths within Bently Nevada FieldMonitor platforms.

    Hardware Specifications

    Parameter Specification
    Model 1034549-40
    Brand Bently Nevada
    Product Type Dual Galvanic Isolator Module
    Origin USA
    Weight Approx. 1.0 kg to 1.5 kg
    Operating Temp -20 deg C to +70 deg C
    Storage Temp -40 deg C to +85 deg C
    Operating Humidity 5% to 95% RH, non-condensing
    Power Consumption Supplied from +19 VDC to +33 VDC input range
    Signal Types Static position and dynamic vibration signals
    Isolation Function Dual-channel galvanic isolation for field transducer circuits
    Compatible Systems FieldMonitor solutions, 170190 Isolator, 1701/06 Isolator Terminal Base
    Installation Type Rack-mounted or modular plug-in configuration
    Safety Compliance Designed for hazardous area applications with ATEX and IECEx requirements

    Eddy-Current Signal Isolation and Rotor Monitoring Characteristics

    The Bently Nevada 1034549-40 supports mechanical monitoring circuits that require isolated transmission between field transducers and monitoring equipment. Moreover, the module maintains signal separation for eddy-current probe based measurements where displacement and vibration data require stable electrical reference control.

    The isolator architecture supports gap voltage validation practices used in Bently Nevada proximity measurement systems. Therefore, engineers can maintain correct probe operating conditions, including the standard -10 VDC target gap voltage reference used for eddy-current probe installations.

    In addition, the module reduces signal interference between monitoring channels through galvanic separation. This function helps limit cross-talk effects in rotor dynamics applications where multiple vibration and position measurements operate within the same protection system.

    Frequently Asked Questions

    Q: Does the 1034549-40 provide direct galvanic separation between field devices and monitoring electronics?
    A: Yes. The module provides electrical isolation between connected field transducer circuits and the monitoring system interface.

    Q: What type of signals can the 1034549-40 isolate?
    A: The module supports both static position signals and dynamic vibration signals from compatible Bently Nevada transducer systems.

    Q: Can the 1034549-40 replace external safety barriers in hazardous area installations?
    A: The module is designed as part of the FieldMonitor hazardous area solution and provides galvanic isolation functions. Installation requirements must follow the applicable system certification and site safety standards.

    Field Installation Guidelines

    • Install the 1034549-40 according to the FieldMonitor system wiring documentation and approved terminal assignments.
    • Separate low-level vibration signal wiring from high-voltage power cables to reduce electrical interference.
    • Connect cable shields according to the system grounding design and avoid creating additional ground loops.
    • Verify transducer polarity, signal routing, and isolation paths before system energization.
    • Confirm hazardous area certification requirements before connecting field devices in classified locations.
    • Inspect terminal connections and module seating during commissioning to ensure correct mechanical installation.

    Spesifikasi

    • Merek: Bently Nevada

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun