Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

ATI3S | Yokogawa Temperature Transmitter Module

ATI3S | Yokogawa Temperature Transmitter Module

Formulir produk

Yokogawa ATI3S Temperature Transmitter Module TheYokogawa ATI3S-00also cataloged astheATI3Stemperature transmitter module, operates as a dedicated hardware component for isolated analog... Baca selengkapnya

SKU: ATI3S-001
Negara asal: JAPAN

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Yokogawa ATI3S Temperature Transmitter Module

    TheYokogawa ATI3S-00also cataloged astheATI3Stemperature transmitter module, operates as a dedicated hardware component for isolated analog signal conversion within CENTUM VP and CENTUM CS 3000 FIO subsystem architectures. TheYokogawa ATI3S-00(ATI3Stemperature transmitter module) provides direct physical/electrical execution of thermocouple, RTD, mV, and resistance signal acquisition into a 4-20 mA HART loop interface.

    Suffix Breakdown & Model Matrix

    • ATI3S-00: Standard configuration without extended environmental or protection options
    • No additional functional suffix definition provided in source data
    • Base series ATI3S: Field I/O temperature transmitter interface family

    Hardware Specifications

    Parameter Specification
    ModelBrand Yokogawa ATI3S-00
    Origin Japan
    Weight Approx. 1.2 kg
    Dimensions Not specified
    OperatingTemp -40 to 85 degC (operation), -50 to 100 degC (storage)
    PowerConsumption Not specified
    Input Types Thermocouple (K, E, J, T, N, R, S, B), RTD (Pt100, JPt100), mV, resistance
    Measurement Range -200 to 1820 degC (sensor dependent)
    Output Signal 4-20 mA with HART protocol
    Accuracy +/-0.1 percent of reading or +/-0.25 degC
    Response Time <= 250 ms
    Stability +/-0.1 percent of span per year
    Housing IP66 / IP67 aluminum alloy

    Yokogawa 4-20 mA HART Loop and Channel Signal Conditioning Characteristics

    The ATI3S architecture implements analog-to-current conversion using a 4-20 mA loop structure with HART digital overlay communication. Within Yokogawa FIO systems, signal acquisition from thermocouples and RTDs is processed with cold junction compensation (CJC) handling integrated at the transmitter level.

    Channel-level behavior is defined by the following electrical characteristics:

    • 4-20 mA loop current scaling for primary process variable transmission
    • HART protocol superimposed digital communication on analog current loop
    • Sensor linearization executed within transmitter firmware domain
    • Input multiplexing across thermocouple and RTD signal classes
    • Environmental drift compensation via internal stability calibration model

    No FOUNDATION Fieldbus or Profibus PA implementation is defined for this module.

    Frequently Asked Questions

    Q1: Does ATI3S support direct thermocouple cold junction compensation externally?
    A1: No external CJC module is required. Cold junction compensation is handled internally within the transmitter signal processing stage.

    Q2: Can ATI3S output be used in non-HART 4-20 mA loops?
    A2: Yes. The analog 4-20 mA signal is primary. HART is superimposed and does not block standard current loop operation.

    Q3: Does the module support resistance and mV inputs simultaneously?
    A3: Input type selection is configuration-based. Only one measurement mode is active per channel configuration instance.

    Field Installation Guidelines

    • Maintain correct polarity on 4-20 mA loop terminals to prevent transmitter non-start condition
    • Use shielded twisted pair cable for thermocouple and RTD input lines
    • Ground cable shield at single point within control cabinet to avoid ground loop formation
    • Avoid routing signal cables parallel to high-voltage switching conductors
    • Ensure IP66/IP67 housing sealing integrity is preserved during enclosure installation
    • Verify sensor type configuration matches wiring input before loop energization

    Spesifikasi

    • Merek: Yokogawa

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun