Yokogawa ANB11D-225/BU2B Node Unit The Yokogawa ANB11D-225/BU2B, also cataloged as the ANB11D Node Unit for Dual-Redundant ESB Bus with Optical...
Baca selengkapnya
Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .
Hubungi kami: +86 135 995 07613
Tersedia pada hari kerja antara pukul 09.00 hingga 18.00
Email kami: sales2@industriaxplc.com
Tersedia 24/7 untuk pertanyaan dan dukungan
Keterangan
Yokogawa ANB11D-225/BU2B Node Unit
The Yokogawa ANB11D-225/BU2B, also cataloged as the ANB11D Node Unit for Dual-Redundant ESB Bus with Optical Repeater, operates as a dedicated hardware component for extending Field I/O connectivity via fiber-optic links within Yokogawa CENTUM VP DCS platforms.
Suffix Breakdown & Model Matrix
Code Segment
Code
Meaning
Model
ANB11D
Node Unit for Dual-Redundant ESB Bus with Optical Repeater
Type
-2
Dual-redundant power supply, for 5 km optical repeater
Power Supply
-2
220 to 240 V AC power supply
Installation
-5
Basic type with no explosion protection
Option Code
/BU2B
Connector Unit with Terminator for ESB Bus
Hardware Specifications
Parameter
Specification
Brand
Yokogawa
Origin
Japan
Weight
Approx. 10.0 kg (fully populated)
Dimensions
19-inch rack mount
Operating Temp
0 to 60 degC (derates to 50 degC with specific comms modules)
Power Consumption
Approx. 230 VA / 120 W
Supply Voltage
220 to 240 V AC (Range: 198 to 264 V AC)
Frequency
50/60 Hz (Range: 47 to 63 Hz)
Distance Capability
Up to 5 km optical fiber link
Module Capacity
Up to 8 FIO modules
4-20mA Loop Protocol and Channel Isolation
The unit interfaces with standard Field I/O (FIO) modules supporting conventional 4-20 mA analog input and output signaling. When configured with HART-enabled FIO modules, the backplane facilitates digital communication superimposed on the analog current loop. Channel-to-channel isolation is maintained within the connected FIO modules to prevent ground loop interference between field devices. The integrated optical repeater converts electrical ESB bus signals to optical signals, ensuring data integrity over extended distances without electromagnetic susceptibility.
Frequently Asked Questions
Q: Does the ANB11D support hot-swapping of FIO modules?
A: FIO module hot-swapping capability depends on the specific module type installed; refer to the individual FIO module manual for live replacement restrictions. Power supply modules in the dual-redundant configuration can typically be replaced online.
Q: What is the function of the /BU2B option?
A: The /BU2B designates a connector unit with an integrated ESB bus terminator. This eliminates the requirement for external terminating resistors at the physical end of the ESB bus segment.
Q: Are there any cooling requirements for this unit?
A: Cooling is achieved via natural air convection. Ensure adequate clearance around the ventilation slots in the 19-inch rack to maintain ambient temperature limits.
Field Installation Guidelines
Mount the unit in a standard 19-inch rack using M5 screws. Ensure the functional grounding terminal (M4 screw) is connected to the panel's ground bus with minimal impedance. When routing the 5 km optical fiber, avoid tight bending radii exceeding the cable manufacturer's specifications to prevent signal attenuation. For ESD protection, ensure all field wiring to the FIO modules is disconnected before installation or removal of the node unit. Verify the power supply voltage matches the 220-240 V AC rating prior to energizing the unit.