Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Allen-Bradley 1769-IR6 CompactLogix RTD Analog Input Module

Allen-Bradley 1769-IR6 CompactLogix RTD Analog Input Module

Formulir produk

Allen-Bradley 1769-IR6 CompactLogix RTD Analog Input Module The Allen-Bradley 1769-IR6, also cataloged as the 1769-IR6 Analog Input Module, operates as... Baca selengkapnya

SKU: 1769-IR6
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    Allen-Bradley 1769-IR6 CompactLogix RTD Analog Input Module

    The Allen-Bradley 1769-IR6, also cataloged as the 1769-IR6 Analog Input Module, operates as a dedicated hardware component for RTD temperature signal acquisition within CompactLogix controller systems.

    Hardware Specifications

    Parameter Specification
    Model 1769-IR6
    Brand Allen-Bradley
    Origin USA
    Product Type RTD Analog Input Module
    Product Line CompactLogix
    Weight 1.00 lb (0.45 kg)
    Operating Temp 32 to 140 deg F
    Storage Temp -40 to 185 deg F
    Power Consumption 1.5 W maximum heat dissipation
    Number of Inputs 6 RTD inputs
    Input Type Resistance Temperature Detector (RTD)
    Input Ranges 0 to 150 Ohms, 0 to 500 Ohms, 0 to 1000 Ohms, 0 to 3000 Ohms
    Converter Type Sigma-Delta analog-to-digital converter
    Current Draw at 5.1 VDC 100 mA
    Current Draw at 24 VDC 35 mA
    Common Mode Voltage -10 to 10 VDC
    Maximum Cable Impedance 25 Ohms
    Input Impedance Greater than 10 MOhms
    Relative Humidity 5 to 95%, non-condensing

    PLC Backplane Communication and I/O Density Scaling

    The 1769-IR6 integrates with Allen-Bradley CompactLogix controllers through the 1769 backplane interface. Therefore, the module transfers processed RTD measurement data directly to the controller memory structure for logic execution and monitoring.

    The module supports six independent RTD input channels, which allows engineers to increase temperature measurement density within CompactLogix I/O assemblies. Additionally, the sigma-delta conversion method provides digital signal conversion for resistance-based temperature measurement applications.

    The module supports selectable resistance ranges, including 0 to 150 Ohms, 0 to 500 Ohms, 0 to 1000 Ohms, and 0 to 3000 Ohms. As a result, users can configure the input characteristics according to different RTD sensor types and temperature measurement requirements.

    Frequently Asked Questions

    Q: Does the 1769-IR6 support direct RTD sensor connection?
    A: Yes. The module accepts RTD resistance signals through six dedicated input channels and converts the measured resistance values into digital data for CompactLogix controller processing.

    Q: What power loading does the 1769-IR6 place on the CompactLogix system?
    A: The module draws 100 mA at 5.1 VDC and 35 mA at 24 VDC according to the specified electrical characteristics.

    Q: Can the 1769-IR6 replace standard analog voltage or current input modules?
    A: No. The 1769-IR6 is designed specifically for RTD resistance measurement and does not provide standard voltage or 4-20 mA analog input functions.

    Field Installation Guidelines

    Install the 1769-IR6 on a compatible CompactLogix 1769 I/O assembly and verify correct module placement before applying system power.

    Connect RTD wiring according to the controller hardware manual and maintain proper separation between sensor cables and high-voltage power conductors. Use shielded instrumentation wiring when the installation environment contains electrical noise sources.

    Terminate cable shields according to the site grounding standard. Avoid unnecessary cable extensions because additional resistance can affect RTD measurement accuracy.

    Before commissioning, verify the configured RTD input range matches the connected sensor specification. Check channel status diagnostics through the controller software to confirm correct signal acquisition.

    Spesifikasi

    • Merek: Allen Bradley

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama