The Allen-Bradley 1756-IRT8I is a high-performance isolated input module designed for the ControlLogix platform. This module provides eight channels capable... Baca selengkapnya

SKU: 1756-IRT8I
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    The Allen-Bradley 1756-IRT8I is a high-performance isolated input module designed for the ControlLogix platform. This module provides eight channels capable of measuring signals from RTDs, thermocouples, and millivolt sources, making it a versatile solution for precise temperature monitoring in industrial automation environments.

    Features

    • Eight isolated input channels for enhanced noise immunity and signal integrity.
    • Supports a wide range of thermocouple types including B, C, D, E, J, K, N, R, S, T, and TXK/XK (L).
    • Data representation in IEEE 32-bit floating point format for high-resolution processing.
    • Fast module scan time of 1 ms to support time-critical control applications.
    • Integrated isolation rated at 250 Volts continuous.

    Technical Specifications

    Module Type Isolated RTD/Thermocouple Input
    Input Channels 8 Isolated
    Backplane Current (5.1V) 200 mA
    Backplane Current (24V) 150 mA
    Max Power Dissipation 4.6 W
    Data Format IEEE 32-bit Floating Point
    Isolation Voltage 250V Continuous

    Installation Guidelines

    • Ensure the ControlLogix chassis is powered down before inserting or removing the 1756-IRT8I module to prevent damage to the backplane or module circuitry.
    • Use appropriate shielded cabling for all thermocouple and RTD inputs to minimize electromagnetic interference (EMI) in high-noise industrial settings.
    • Maintain proper grounding practices for the chassis to ensure effective noise shielding.
    • Verify that the module is fully seated in the chassis slot and that the retaining screws are tightened to secure the connection.
    • Ensure adequate ventilation in the cabinet to manage the 4.6W maximum heat dissipation.

    FAQ

    What types of sensors can be connected to the 1756-IRT8I?
    This module supports various RTDs, multiple thermocouple types (B, C, D, E, J, K, N, R, S, T, and L), and millivolt input signals.

    Does this module require external power for the inputs?
    The module draws its required power from the ControlLogix backplane. Refer to the current draw specifications (200mA at 5.1V and 150mA at 24V) when calculating total chassis power supply loading.

    Spesifikasi

    • Merek: Allen-Bradley

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun