Lebih dari 100.000 Suku Cadang PLC, DCS, Drive, TSI & MRO Tersedia Pelajari lebih lanjut

Allen-Bradley 1756-IR6I ControlLogix 6-Point Isolated RTD Input Module

Allen-Bradley 1756-IR6I ControlLogix 6-Point Isolated RTD Input Module

Formulir produk

The Allen-Bradley 1756-IR6I is a high-performance isolated RTD input module designed for the ControlLogix platform. This module provides six isolated... Baca selengkapnya

SKU: 1756-IR6I
Negara asal: USA

      100% Asli dan Autentik

    Butuh stok banyak? Hubungi kami .

      100% Baru, Siap kirim

    Butuh stok banyak? Hubungi kami .

      Dukungan Pengembalian Dana, Layanan 7X24 jam

    Dukungan Pengembalian Dana, Layanan 7X24jam, Hubungi kami .

      Hubungi kami: +86 135 995 07613

    Tersedia pada hari kerja antara pukul 09.00 hingga 18.00

      Email kami: sales2@industriaxplc.com

    Tersedia 24/7 untuk pertanyaan dan dukungan

    Keterangan

    The Allen-Bradley 1756-IR6I is a high-performance isolated RTD input module designed for the ControlLogix platform. This module provides six isolated input channels, allowing for precise temperature measurement in industrial environments where electrical isolation is required to prevent ground loops and signal interference. It is engineered to support a variety of RTD sensor types, including 100, 200, 500, and 1000 Ohm Platinum sensors, offering 16-bit resolution for accurate data acquisition.

    Features

    • Six isolated RTD input channels for enhanced signal integrity.
    • 16-bit resolution for high-precision temperature monitoring.
    • Compatible with common Platinum RTD standards (100, 200, 500, 1000 Ohm).
    • Designed for seamless integration into the ControlLogix backplane.
    • Robust construction for demanding industrial automation applications.

    Technical Specifications

    Model 1756-IR6I
    Input Channels 6 Isolated RTD
    Resolution 16-bit
    Power Dissipation (Max) 4.3 Watts
    Backplane Current (24V) 125 mA
    Off-State Input Current 2.75 mA
    Manufacturer Allen-Bradley

    Installation Guidelines

    • Ensure the ControlLogix chassis is powered down before inserting or removing the module to prevent electrical damage.
    • Verify that the module is fully seated in the chassis slot and secured with the top and bottom latches.
    • Use shielded twisted-pair cabling for RTD connections to minimize electromagnetic interference (EMI).
    • Maintain proper grounding practices for the chassis and field wiring to ensure the effectiveness of the channel isolation.
    • Ensure adequate airflow within the cabinet to stay within the module's operating temperature limits.

    FAQ

    What types of RTD sensors are compatible with the 1756-IR6I?
    This module is compatible with 100, 200, 500, and 1000 Ohm Platinum RTD sensors.

    Is the 1756-IR6I electrically isolated?
    Yes, the module features six isolated input channels, which help protect the system from potential ground loop issues and common-mode noise.

    Spesifikasi

    • Merek: Allen-Bradley

    • :

    Keuntungan

    • Keandalan tinggi di lingkungan industri

    • Mendukung operasi berkelanjutan
    • Kompatibel dengan sistem PLC/DCS utama

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    Kirimkan pesan kepada kami!

    Butuh stok banyak? Hubungi kami.

    Koleksi yang mungkin Anda sukai

    Produk yang baru saja dilihat

      Login

      Lupa kata sandi Anda?

      Belum punya akun?
      Buat akun